Standard Pump SPFP30NPS Скачать руководство пользователя страница 2

spfp30sm-rev0

516

www

.

standardpump

.

com

IMPORTANT

Read the safety warnings and instructions in this manual 

before pump installation and start-up. Failure to comply with 

the recommendations stated in this manual could damage the 

pump and void factory warranty.

When used for toxic or aggressive fluids, the pump should 

always be flushed clean prior to disassembly.

Airborne particles and loud noise hazards. Wear eye and ear 

protection.

Before maintenance or repair, shut off the compressed air line, 

bleed the pressure, and disconnect the air line from the pump. 

Be certain that approved eye protection and protective clothing 

are worn at all times. Failure to follow these recommendations 

may result in serious injury or death.

To be fully groundable, the pumps must be ATEX Compliant.

Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection.

To reduce the risk of static electrical sparking, this pump must be grounded. Check the local 

electrical code for detailed grounding instruction and the type of equipment required.

When the pump is used for materials that tend to settle out 

or solidify, the pump should be flushed after each use to 

prevent damage. In freezing temperatures the pump should be 

completely drained between uses.

Before pump operation, inspect all fasteners for loosening 

caused by gasket creep. Retighten loose fasteners to prevent 

leakage. Follow recommended torques stated in this manual.

CAUTION

WARNING

Nonmetallic pumps and plastic components are not UV 

stabilized.  Ultraviolet radiation can damage these parts and 

negatively affect material properties. Do not expose to UV light 

for extended periods of time.

In the event of diaphragm rupture, pumped material may enter 

the air end of the pump, and be discharged into the atmosphere. 

If pumping a product that is hazardous or toxic, the air exhaust 

must be piped to an appropriate area for safe containment.

This pump is pressurized internally with air pressure during 

operation. Make certain that all fasteners are in good condition 

and are reinstalled properly during reassembly.

Take action to prevent static sparking. Fire or explosion can 

result, especially when handling flammable liquids. The pump, 

piping, valves, containers and other miscellaneous equipment 

must be properly grounded.

Safety Information

Grounding the Pump

WARNING

Take action to prevent static sparking. 

Fire or explosion can result, especially 

when handling flammable liquids. The 

pump, piping, valves, containers or  

other miscellaneous equipment must 

be grounded.

WARNING

Pump not designed, tested or certified to be powered by 

 

compressed natural gas. Powering the pump with natural  

gas will void the warranty.

Use safe practices when lifting

kg

UNIVERSAL ALL AODD

Содержание SPFP30NPS

Страница 1: ...FP30NPS SPFP30SSS SPFP30SST STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth Ga 30097 Phone 770 307 1003 www standardpump com 3 Food Processing Service Operating Manual 1 PUMP SPECS 2 INSTAL OP 3...

Страница 2: ...uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonm...

Страница 3: ...eration Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 7 Composite Drawings Parts List Materials Code SECTION 4 CERTIFICATES 11 EC Declaration of Conformity Directive 2006 42 EC Ma...

Страница 4: ...lt in deviations in excess of 5 NOTE Performance based on the following PTFE fitted pump flooded suction water at ambient conditions The use of other materials and varying hydraulic conditions may res...

Страница 5: ...ifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures 220 F 104 C 35 F 37 C Maximum and Minimum Temperatures are the limits for which these materials can be oper...

Страница 6: ...LAMP DISCHARGE FLANGE 3 57 O D TRI CLAMP SUCTION FLANGE 1 2 NPT AIR INLET 1 NPT AIR EXHAUST 32 01 813 05 16 96 430 66 3 46 87 96 40 10 16 NOTES 1 THE DIMENSIONS ON THIS DRAWING ARE FOR REFERENCE ONLY...

Страница 7: ...suction piping and across the suction side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The sucti...

Страница 8: ...ter in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to...

Страница 9: ...lds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not app...

Страница 10: ...4 25 26 27 29 30 31 32 33 34 37 38 39 35 36 40 41 41 39 40 28 11 REV REVISION CHG DATE APP DATE ECN THIS IS A PROPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION O...

Страница 11: ...200 211 200 320 200 433 200 437 15 2 Air Chamber Gasket 16 8 Bolt 200 327 200 232 200 223 200 227 200 239 200 221 200 217 17 1 Pilot Sleeve Assembly include item 18 18 6 O ring 19 1 Retaining Ring 20...

Страница 12: ...OPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC DESCRIPTION DRAWING NUMBER WARREN RUPP INC REV 01 E3Sx5xxx0C FP ATEX E3 FP PTFE FITTED PUMP To...

Страница 13: ...ir Chamber 200 211 200 320 200 433 200 437 15 2 Air Chamber Gasket 16 8 Bolt 200 331 200 232 200 223 200 227 200 242 200 221 200 217 17 1 Pilot Sleeve Assembly Include item 18 18 6 O ring 19 1 Retaini...

Страница 14: ...TUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMIT CONFORMITEITSVERKLARING DEKLARATION OM VERENSST MMELSE EF OVERENSSTEMMELSESERKL RING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKL RING DECLARA AO DE CONFO...

Страница 15: ...7 USA On File With DEKRA Certification B V 0344 Meander 1051 6825 MJ Arnhem The Netherlands Harmonized Standards Applied BS EN 13463 1 2009 Non Electrical Equipment Potentially Explosive Atmospheres P...

Страница 16: ...d Contact Materials Signature of authorized person Revision Level B Printed name of authorized person Chris Murphy Director of Operations October 13 2015 Date of issue September 11 2013 Title Date of...

Отзывы: