Standard Pump SPFP30NPS Скачать руководство пользователя страница 11

spfp30sm-rev0

516

Model SPFP30 Food Processing • 

8

www

.

standardpump

.

com

Composite Repair Parts List - FDA Santoprene Fitted

Air Valve Assembly

Item #

Qty.

Description

Part Number

Nickle Plated

Stainless Steel

1

1

Valve Body (includes items 2-11)

200-460

200-206

200-429

200-431

2

1

Valve Body

3

1

Valve Body Gasket

200-277

200-235

200-224

200-238

200-307

4

1

Valve Sleeve

5

6

O-ring

6

1

Valve Spool Assembly (Includes items 7)

7

6

Glyde Ring Assembly

8

1

Air Valve Screen

200-279

200-439

9

2

End Cap Gasket

200-278

200-332

200-324

10

2

End Cap

11

13

Mounting Screws

Center Section Assembly

Item #

Qty.

Description

Part Number

Nickle Plated

Stainless Steel

12

1

Center Block Assembly (Includes item 13)

200-308

200-442

13

2

Main Shaft O-Ring

200-309

14

2

Air Chamber

200-211

200-320

200-433

200-437

15

2

Air Chamber Gasket

16

8

Bolt

200-327

200-232

200-223

200-227

200-239

200-221

200-217

17

1

Pilot Sleeve Assembly (include item 18)

18

6

O-ring

19

1

Retaining Ring

20

1

Pilot Spool Assembly (Includes item 21)

21

7

O-ring

22

1

Muffler

Diaphragm Assembly / Elastomers

Item #

Qty.

Description

Part Number

SPFP30NPS

SPFP30SSS

FDA Santoprene

FDA Santoprene

23

1

Main Shaft

200-306

200-417

200-365

24

2

Diaphragm

25

2

Outer Diaphragm Plate

26

2

Inner Diaphragm Plate

200-366

200-449

27

12

Bolt

200-367

200-368

200-283

200-415

200-398

200-400

28

12

Washer

29

2

Bumper Washer

30

2

Back-Up Washer

31

4

Valve Seat

32

4

Valve Ball

Wet End Assembly

Item #

Qty.

Description

Part Number

33

2

Water Chamber

200-372

200-370

200-371

200-268

200-373

200-374

200-375

200-376

200-269

34

4

Large Clamp Half

35

4

Bolt

36

4

Large Wing Nut

37

1

Discharge Manifold

38

1

Suction Manifold

39

8

Small Clamp Half

40

8

Bolt

41

8

Small Wing Nut

MODEL SPECIFIC

3: EXP

 VIEW

Содержание SPFP30NPS

Страница 1: ...FP30NPS SPFP30SSS SPFP30SST STANDARD PUMP INC 1610 Satellite Blvd Suite D Duluth Ga 30097 Phone 770 307 1003 www standardpump com 3 Food Processing Service Operating Manual 1 PUMP SPECS 2 INSTAL OP 3...

Страница 2: ...uses Before pump operation inspect all fasteners for loosening caused by gasket creep Retighten loose fasteners to prevent leakage Follow recommended torques stated in this manual CAUTION WARNING Nonm...

Страница 3: ...eration Typical Installation Guide Troubleshooting SECTION 3 EXPLODED VIEW 7 Composite Drawings Parts List Materials Code SECTION 4 CERTIFICATES 11 EC Declaration of Conformity Directive 2006 42 EC Ma...

Страница 4: ...lt in deviations in excess of 5 NOTE Performance based on the following PTFE fitted pump flooded suction water at ambient conditions The use of other materials and varying hydraulic conditions may res...

Страница 5: ...ifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures 220 F 104 C 35 F 37 C Maximum and Minimum Temperatures are the limits for which these materials can be oper...

Страница 6: ...LAMP DISCHARGE FLANGE 3 57 O D TRI CLAMP SUCTION FLANGE 1 2 NPT AIR INLET 1 NPT AIR EXHAUST 32 01 813 05 16 96 430 66 3 46 87 96 40 10 16 NOTES 1 THE DIMENSIONS ON THIS DRAWING ARE FOR REFERENCE ONLY...

Страница 7: ...suction piping and across the suction side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The sucti...

Страница 8: ...ter in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve can be opened to...

Страница 9: ...lds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not app...

Страница 10: ...4 25 26 27 29 30 31 32 33 34 37 38 39 35 36 40 41 41 39 40 28 11 REV REVISION CHG DATE APP DATE ECN THIS IS A PROPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION O...

Страница 11: ...200 211 200 320 200 433 200 437 15 2 Air Chamber Gasket 16 8 Bolt 200 327 200 232 200 223 200 227 200 239 200 221 200 217 17 1 Pilot Sleeve Assembly include item 18 18 6 O ring 19 1 Retaining Ring 20...

Страница 12: ...OPRIETARY DOCUMENT DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC DESCRIPTION DRAWING NUMBER WARREN RUPP INC REV 01 E3Sx5xxx0C FP ATEX E3 FP PTFE FITTED PUMP To...

Страница 13: ...ir Chamber 200 211 200 320 200 433 200 437 15 2 Air Chamber Gasket 16 8 Bolt 200 331 200 232 200 223 200 227 200 242 200 221 200 217 17 1 Pilot Sleeve Assembly Include item 18 18 6 O ring 19 1 Retaini...

Страница 14: ...TUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMIT CONFORMITEITSVERKLARING DEKLARATION OM VERENSST MMELSE EF OVERENSSTEMMELSESERKL RING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKL RING DECLARA AO DE CONFO...

Страница 15: ...7 USA On File With DEKRA Certification B V 0344 Meander 1051 6825 MJ Arnhem The Netherlands Harmonized Standards Applied BS EN 13463 1 2009 Non Electrical Equipment Potentially Explosive Atmospheres P...

Страница 16: ...d Contact Materials Signature of authorized person Revision Level B Printed name of authorized person Chris Murphy Director of Operations October 13 2015 Date of issue September 11 2013 Title Date of...