Operation 

1. Before starting the pump 

a. After completing installation, measure the insulation resistance again as described in Installation. 

b. Check water level. 

If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water 

level, the motor protector will be activated. Constant repetition of this action will shorten pump service life. Do 

not start the pump again in such a situation until after the motor has completely cooled. 

 

2. 

Test operation…. 

Non-automatic pump 

Automatic pump

 

a. Turn the operating switch on and off a couple of times to check for normal pump start. 

Floating switch must be raised for the pump to start. 

b. Next, check direction of rotation. If discharge volume is low or unusual sounds are heard when the pump is  

operating, rotation has been reversed. When this happens, reverse two of the wires. 

 

Maintenance 

Check pressure, output, voltage, current and other specifications. Unusual readings may indicate. 

Refer to Troubleshooting and correct as soon as possible. 

 

1. 

Daily inspections

 

Check current and ammeter fluctuation daily. If ammeter fluctuation is great, even though within the limits of pump 

rating, foreign matter may be clogging the pump. If the quantity of liquid discharged falls suddenly, foreign matter 

may be blocking the suction inlet. 

 

2. Regular inspections 

Monthly inspections 

Measure the insulation resistance. The value should be more than 

1M ohm

. If resistance starts to fall rapidly even 

with an initial indication of over 1M ohm, this may be an indication of trouble and repair work is required. 

 

Annual inspections 

To prolong the service life of the mechanical seal by replacing the oil in the mechanical seal chamber once a year. 

Water mixed the oil or cloudy textures are indications of a defective mechanical seal requiring replacement. When 

replacing the oil, lay the pump on its side with filler plug on top. Inject suitable amount turbine oil No.32 (ISO VG-32) 

Inspections at 3-5year intervals 

Conduct an overhaul of the pump. These intervals will preclude the possibility of future trouble. 

 

3. 

Parts that will need to be replaced

 

Replace the appropriate part when the following conditions are apparent. 

 

 

Replaceable part 

Mechanical seal 

Oil filler plug O-ring 

Lubricating oil 

O-ring 

 

Replacement guide 

Whenever oil in 

mechanical seal 

chamber is clouded 

Whenever oil is replaced 

or inspected 

 

Whenever clouded or dirty  Whenever pump is 

overhauled 

Frequency 

Annually 

A half yearly 

A half yearly 

Annually 

 

Note: above replacement schedule is based on normal operating conditions

 

 

Motor output 

1.5HP 

2HP 

3HP 

Mechanical seal 

15Ø 

Oil seal 

15Ø

24Ø

7 t 

Oil filler plug O-ring 

(

Inner diameter) x (outer diameter) x (thickness) 

7.52Øx14.5Øx3.53 t 

Lubricating oil 

(

turbine oil #32) 

280 cc 

Содержание SEW Series

Страница 1: ...EI 700 006 REV 1 Installation Operation and Maintenance Manual Stancor SEW Series Pumps _______________________________________________________________________...

Страница 2: ...h the exception of shortening the cord to fit into a control panel Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with...

Страница 3: ...o during rainstorms water may be present in the surrounding area of the pump Caution must be used to prevent bodily injury when working near the pump Electrical power should be disconnected prior to t...

Страница 4: ...uring shipment Are any bolts or nuts loose Have all necessary accessories been supplied For a list of standard accessories see Construction We recommend that you keep a spare pump on hand in case of e...

Страница 5: ...op 6 Do not permit end of discharge piping to besubmerged as backflow will result when the pump is shut down 7 WARNING Non automatic pumps do not have an automatic operating system Do not operate the...

Страница 6: ...may be blocking the suction inlet 2 Regular inspections Monthly inspections Measure the insulation resistance The value should be more than 1M ohm If resistance starts to fall rapidly even with an ini...

Страница 7: ...7 Construction SEW DN 1 5 2HP...

Страница 8: ...200 11 Impeller FC 200 NO Name Mtrl NO Name Mtrl 1 Cable H07RN F SJTOW STOW 20 5 Washer SUS 304 13 Protector 3 Phase 20 7 Washer SUS 304 14 Capacitor 1 Phase 21 1 Spring Washer SUS 304 19 Screw SUS 30...

Страница 9: ...9 Construction SEW DN 3HP...

Страница 10: ...200 11 Impeller FC 200 NO Name Mtrl NO Name Mtrl 1 Cable H07RN F SJTOW STOW 20 5 Washer SUS 304 13 Protector 3 Phase 20 7 Washer SUS 304 14 Capacitor 1 Phase 21 1 Spring Washer SUS 304 19 Screw SUS 3...

Страница 11: ...filler plug and drain lubricating oil 4 Remove intermediate casing bolts and oil chamber Remember that any lubricating oil remaining in the mechanical seal chamber will flow out 5 Carefully remove mec...

Страница 12: ...ation 3 Correct rotation Does not pump Inadequate vol ume 1 Reverse rotation 1 Correct rotation see Operation 2 Significant drop in voltage 2 Contact electric power company 3 Operating a 60Hz pump wit...

Страница 13: ...Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA 860 399 5937 www flowsolutions com Stancor is a trademark of Industrial Flow Solutions Operating LLC All rights...

Отзывы: