CHARACTERISTICS OF THE DEVICE

1. 

Broad scope of measurement

 

Rotating probe

 

Low battery use

 

Stainless steel probe

 

Pocket size

 

Max/min temperature memory

 

Hold reading function

 

Possibility to display measurement in two different scales: Celsius and Fahrenheit

 

TECHNICAL SPECIFICATION

2. 

Range of measurement

-50 ~ 300 ° C/- 58 ~ 572°F

Accuracy of the display

±2° C between –50 ~ -20°C / ±3.6° F between –58 ~ -4°F

±1° C between –20 ~ 150°C / ±1.8° F between -4oF ~ 302oF
±3° C between 150 ~ 250°C / ±5.4° F between 302° F ~ 482°F
±4° C between 250 ~ 300° C / ±7.2° F between 482° F ~ 572°F

Minimum read on the display

0.1°  within range

Alarm setting accuracy

1°  within range

Update frequency of the temperature reading

1 Second

Temperature unit

°C or °F factory settings

Automatic disabling of the device

After 10 minutes of inactivity

The display size

28 (W) x 16 (H) mm

Battery

1.5 Volt, type AAA (sold without batteries)

Battery Life

Ca. 8,000 hours continuous work

The probe dimensions

3.5 (Ø) x 1 5 (length) mm

Dimensions of the device

52 (W) x 160 (H) mm

Working temperature

0 ~ 50 °C / 32 ~ 122 °F

INSTALLATION

3. 

Open the battery container

1. 

Install battery, mind the polarity (+/-)

2. 

Close the battery container lid.

3. 

OPERATING THE DEVICE

4. 

MEASUREMENT

4.1. 

Pull the probe and turn it clockwise to set it at the desired angle

1. 

Place the probe in the product intended for measurement, insert it to a depth of 25mm (1”) and read the temperature.

2. 

UNIT OF TEMPERATURE MEASUREMENT

4.2. 

Press and hold the  [°C/°F] button for about 3 seconds, then release the button and choose the unit of measurement