1. Safety Instruction

You have to carefully read the instruction, which includes impor-

tant information about the installation, usage and maintenance.

• 

Please keep this User Guide for future consultation. If you sell the unit 

to another user, be sure that he also receives this instruction booklet.

• 

Unpack and check carefully there is no transportation damage before 

using the unit.

• 

Before operating, ensure that the voltage and frequency of power sup-

ply match the power requirements of the unit as stated in this manual.

• 

It’s important to ground the yellow/green conductor to earth in order to 

avoid electric shock.

• 

The unit is for indoor use only. Use it only in a dry location. Exposing the 

device to rain or moisture would cause the risk of electrical shock or fire.

• 

The unit must be installed in a location with adequate ventilation, at 

least 50 cm from adjacent surfaces. Be sure that no ventilation slots are 

blocked.

• 

Disconnect the device from the mains power before any servicing or 

maintenance.

• 

Maximum ambient temperature is TA: 40°C. Don’t operate it where the 

temperature is higher than this.

• 

In the event of serious operating problem, stop using the unit imme-

diately. Never try to repair the unit by yourself. Repairs carried out by 

unskilled people can lead to damage or malfunction. Please contact the 

nearest authorized technical assistance centre. Always use the same 

type spare parts.

• 

Do not connect the device to any dimmer pack.

•  Do not look directly at the LED light beam while the fixture is on.
•  There are no user serviceable parts inside the fixture. Do not open the 

housing or attempt any repairs by yourself. If the fixture shows any vis

-

ible damage or in the unlikely event, that your fixture may require serv

-

ice, please contact your nearest dealer.

• 

Due to the magnifying type lens, please keep the lens out of contact 

with direct sunlight. Direct sunlight can cause heat to build up inside of 

the unit, which will seriously damage the device.

• 

Don’t connect more that 20 units to one AC mains power supply lead. 

Otherwise it could be overloaded and break down.

Содержание MATRIXX FX-440 DMX

Страница 1: ...Owner s Manual LED MATRIX FLOWER EFFECT MATRIXX FX 440 DMX...

Страница 2: ...le of Contents 1 Safety Instruction 3 2 Technical Specification 4 3 How To Setup The Unit 5 3 1 Control Panel 5 3 2 Main Function 6 4 How To Control The Fixture 9 4 1 Master Slave pre prog Function 9...

Страница 3: ...device from the mains power before any servicing or maintenance Maximum ambient temperature is TA 40 C Don t operate it where the temperature is higher than this In the event of serious operating prob...

Страница 4: ...ing and zooming effects Great built in lighting shows under Master Slave operation triggered by music Optional CA 8 easy controller for enjoying instant lighting shows at you fingertips LED display fo...

Страница 5: ...ion Button y MENU To select the programming functions u DOWN To go backward in the selected functions i UP To go forward in the selected functions o ENTER To confirm the selected functions a Sensitivi...

Страница 6: ...t any of the given functions press the MENU button until the required one is shown in the display Select the function by pressing the ENTER button and the display will blink Use the DOWN UP buttons to...

Страница 7: ...go back to the functions without any change press the MENU button Slave mode Press the MENU button up to when the is shown on the display Press the ENTER button and the display will blink Use the DOWN...

Страница 8: ...again Display inverse Press the MENU button until is blinking on the display Use DOWN UP button to select normal or inverse press ENTER button to setup Back to the functions without any change press M...

Страница 9: ...master LED will be constantly on and sound LED will flash to the music The other units will have to select nor mal or 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain a...

Страница 10: ...y will blink Use the DOWN UP button to change the DMX512 address Once the address has been selected press and keep the ENTER button pressed up to when the display stops blinking or storing automatical...

Страница 11: ...this mode you can control the 144 LEDs separately 6 DMX512 Connection The DMX 512 is widely used in intelligent lighting control with a maximum of 512 channels 1 Connect the fixture together in a dais...

Страница 12: ...ollowing are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the mains powe...

Страница 13: ...or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the exter...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...2010 Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...

Отзывы: