www.thomann.de
DJ Lase 40-G MKII / 100-R MKII / 150-B
9
Operation
Start the device
Perform the following steps to start the operation:
1. Verify that all required laser safety precautions have been taken. Make sure that there is no one in the
reach of the laser beam.
2. Insert the safety key (8) and turn it to the “OFF” position.
3. If not already connected, connect the device to the mains (6).
4. Using the main switch (4) turn the device on. After a few seconds, the fan and the motors start to work.
The display shows the current operation mode. The device is now operational.
5. Turn the safety key (8) to the “ON” position to turn the laser beam on.
Main menu
Press “FUNC” to activate the main menu and to select one of the operation modes.
When the display flashes, use the “UP” and “DOWN” buttons to change the displayed value. When the display
shows the desired value, press “ENTER”. To go back to the main menu without any changes, press “FUNC” or
wait for one minute.
All settings that were made previously are kept, even if you disconnect the device from the power supply.
Auto show mode
Aut
Press “FUNC” until the display shows “Aut”. The device operates in stand-alone mode and displays a
pre-programmed show. Press “ENTER” to confirm and to start the operation.
Music mode
SoU
Press “FUNC” until the display shows “SoU”. The device operates in stand-alone mode, the built-in
microphone controls a pre-programmed show. Press “ENTER” to confirm and to start the operation.
Sound sensitivity
S 6
Press “FUNC” until the display shows “S 6” and starts flashing. This menu is used to set the sensitiv-
ity of the microphone. Using the “UP” and “DOWN” buttons, you can now choose between “S 0”
(sensitivity = 0, music mode disabled) and “S 1” (low sensitivity) to “S 9” (high sensitivity). Press “ENTER” to
store the setting.
DMX mode
001
Press “FUNC” until the display shows “001”. You can now set the number of the first DMX channel of
the device (DMX address). Select a value between 1 and 512 using the “Up” and “Down” buttons.
Press “ENTER” to store the value and to start the operation in DMX mode.
Ensure that this channel number fits to the configuration of your DMX controller. Since the device uses eight
DMX channels, the highest usable DMX start address is 505.
Master/slave mode
SLA
Press “FUNC” until the display shows “SLA”. In this mode, the device exactly follows the operation of
the “master” it is connected to. Press “ENTER” to confirm and to start the operation.
Stop the device
Perform the following steps to stop the operation:
1. Turn the safety key (8) to the “OFF” position to turn the laser beam off and remove the key. Keep the safety
key under control.
2. Using the main switch (4) turn the device off.
3. Optionally, disconnect the device from the mains (6).