GRP Flameproof Visual Signal - 5 Joule

Series FL6S

For further technical data, see www.r-stahl.com.

6

Transport and storage

• Transport and store the device only in the original packaging.

• Store the device in a dry place (no condensation) and vibration-free.

• Do not drop the device.

Technical Data
Electrical data

Rated operational 

voltage

24 or 48 V DC

115 or 230 V AC

Current consumption

Operational  

parameters

+

/

-

10 %

Line monitoring

yes

Inrush current

Luminous characteristics

Light source

Xenon flash tube

Flash energy

5 J

Flash rate

1/s

Light intensity

Lens colour

amber, red, green, opal, blue, clear, yellow, magenta

Mechanical data

Material

Enclosure

glass reinforced polyester 

Lens cover

polycarbonate

Wire guard

stainless steel

Assembly parts

stainless steel

Bracket

stainless steel

Labels

polyester foil, adhesive

Degree of protection IP66 / IP67 acc. to IEC 60529

Mounting / Installation

Connection

2.5 mm

2

 terminals

24 V DC

320 mA

48 V DC

170 mA

115 V AC

204 mA

230 V AC

75 mA

24 V / 48 V DC

115 V AC

230 V AC

I

max

duration

I

max

duration

I

max

duration

3.2 A

220 μs

11 A

500 μs

8 A

50 μs

Effective candela 

(cd)

Luminous flux  

(Im)

clear

62

12.5

Содержание FL6S Series

Страница 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www r stahl com EN GRP Flameproof Visual Signal 5 Joule Series FL6S...

Страница 2: ...arning notes 4 2 3 Symbols on the device 5 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Modifications and alterations 6 4 Function and device design 6 4 1 Function 6 5 Tech...

Страница 3: ...affairs 1 3 Further documents Data sheet For documents in additional languages see www r stahl com 1 4 Conformity with standards and regulations See certificates and EC Declaration of Conformity www...

Страница 4: ...on The warning notes have the following structure Signalling word DANGER WARNING CAUTION NOTICE Type and source of danger damage Consequences of danger Taking countermeasures to avoid the danger or da...

Страница 5: ...es on the device Use the device in accordance with its intended and approved purpose only We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these op...

Страница 6: ...ing evacuating the occupants of the buildings structures In hazardous areas the devices have explosion protection for ATEX IECEx Zones 1 2 for gas and 21 22 for dust Gas groups covered are IIB IIC and...

Страница 7: ...31 2013 E II 2 G Ex d IIB T Ta Ta C Gb E II 2 G Ex d IIC T Ta Ta C Gb E II 2 D Ex tb IIIC T C Ta C Db IP66 Product variant table Certifications and certificates Certificates IECEx ATEX Kazakhstan TR R...

Страница 8: ...nal parameters 10 Line monitoring yes Inrush current Luminous characteristics Light source Xenon flash tube Flash energy 5 J Flash rate 1 s Light intensity Lens colour amber red green opal blue clear...

Страница 9: ...ation 7 1 Dimensions fastening dimensions Dimensional Drawings All Dimensions in mm inches Subject to Alterations 17149E00 16920E00 GRP Visual Signal Series FL6S with L Bracket GRP Visual Signal Serie...

Страница 10: ...cted from dust and dirt Install the end flanges squarely without applying any force Do not use a hammer or other tools when working on the flanges and do not use the fixing screws to pull down the fla...

Страница 11: ...rews 6 and remove strobe flange 5 Prepare cable gland Ensure earth connection Install cable gland Connect cables see electrical connection Fix bracket to wall Attach device 17161E00 17225E00 17158E00...

Страница 12: ...ards device Connect PCB using the plug Install strobe flange Replace cheese head screws M5 x 25 see information below and tighten the screws with a tightening torque of 4 Nm 7 2 4 Electrical Connectio...

Страница 13: ...es may be connected as a single system loop See wiring diagrams for further information Circuit diagrams The terminals accept wires of 2 5 mm2 or 14 to 18 AWG Line monitoring for devices with DC by re...

Страница 14: ...tallation 17191E00 Earth connection WARNING Danger of electric shock due to energised parts Non compliance can result in severe or fatal injuries All connections and wiring must be disconnected from t...

Страница 15: ...odies are inside the device the device is sealed according to regulations flash circuit board is connected 9 Operation The device is used to warn and alert by means of a visual signal 24 V DC and 48 V...

Страница 16: ...y be carried out by appropriately authorized and qualified electricians Observe the relevant national regulations in the country of use Check Measures the permissible ambient temperature If exceeding...

Страница 17: ...rm select Request RMA slip Fill out the form and send it Confirmation will be sent R STAHL s customer service will contact you You will receive an RMA slip after speaking with customer service Send th...

Страница 18: ...isposal Separate materials when sending it for recycling Ensure environmentally friendly disposal of all components according to the statutory regulations 13 Accessories and Spare parts NOTE Malfuncti...

Страница 19: ......

Отзывы: