Visual signalling device
Series FL60/2
5
Technical data
Explosion protection
Global (IECEx)
Gas and dust
IECEx EPS 20.0037X
Ex db IIC T.
*)
Gb
Ex tb IIIC T... °C
*)
Db
Europe (ATEX)
Gas and dust
EPS 20 ATEX 1 077 X
E
II 2 G Ex db IIC T.
*)
Gb
E
II 2 D Ex tb IIIC T... °C
*)
Db
*)
Temperature class
T6
T4
Max. surface temperature (tb)
T80 °C
T100 °C
Ambient temperature range (db)
-
45 to +50 °C
1)
-
45 to +70 °C
2)
Ambient temperature range (tb)
-
35 to +50 °C
1)
-
35 to +70 °C
2)
1)
Loop in/loop out wiring up to max. 10 A
2)
Loop in/loop out wiring up to max. 10 A, connection line and cable entries with
permissible operating temperature ≥ +90 °C required
Special conditions "X"
Repair work on flameproof joints is only permissible in accordance with the
values specified by the manufacturer.
The protective covers must be installed so that they are protected against
electrostatic charge.
The ambient temperature range for dust applications is max. -35 to +50 °C or
+70 °C.
For gas Ex applications, the ambient temperature can be as low as -45 °C.
The strength class of the screws used must be at least A2-70.
Certifications and certificates
Certificates
IECEx, ATEX