7.3.2 Electrical connections
• Lay the pre-installed cabling in the intended electrical connections – see figure.
DANGER
Explosion hazard due to insufficient protective measures!
Non-compliance results in severe or fatal injuries.
• Select suitable cables to ensure that the maximum permissible
conductor temperatures are not exceeded.
• When using core end sleeves, attach them using a suitable tool.
• The conductor insulation must be touching the terminal.
• Do not damage the conductor (e.g. nicking) when stripping it.
• Finally, check the conductor to ensure that it is secure (fixed).
22796E00
22797E00
5
Power supply
6
Control (A/B signal)
6
5
LED
0V 24V
6
5
B A