Termination board and
connecting cable for Zone 2
Series 9491
Dismounting
22372E00
Pry open both snap catches one after the other with a screwdriver.
Swing the bottom edge of the device forwards and move the device upwards to remove it.
6.2
Installation
6.2.1 Termination Board Type 9491/T1-08-0.
Operation under difficult conditions, in particular on ships, requires additional
measures to be taken for correct installation, depending on the operating location.
Further information and instructions on this can be obtained from your regional sales
contact upon request.
DANGER! Explosion hazard due to ignition sparks during work on a device that has
not been fitted securely!
Non-compliance may result in fatal or serious injuries.
Tighten the screws to the specified tightening torques.
DANGER! Explosion hazard due to ignition sparks caused by insufficient insulation!
Non-compliance may result in fatal or serious injuries.
Only use core end sleeves with insulation.
Observe the minimum length of the stripped conductor
(see "Technical data" chapter).