Mounting and installation
13
(Double) temperature controller and
limiter
Series 8146/5041, 8146/5051
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7.2.4 Operating position
7.3
Installation
16523E00
• Alignment of enclosure
depending on mounting type:
• For vertical mounting:
any alignment
• For horizontal mounting:
cover on top
• Hanging position/overhanging
cover is not permitted!
DANGER
Explosion hazard due to impermissible cable glands!
Non-compliance results in severe or fatal injuries.
• Use only cable glands approved for the required type of protection.
• When selecting cable glands, observe the thread type and thread size
in the equipment documentation.
• Make sure that the conductor diameter matches the clamping
cross-section of the cable glands.
DANGER
Explosion hazard due to incorrectly laid cables in the Ex e enclosure!
Non-compliance results in severe or fatal injuries.
• Adhere to the required creepage distances and clearances.
• Fasten mounting rails or elements properly.
DANGER
Explosion hazard due to cable glands without strain relief!
Non-compliance results in severe or fatal injuries.
• Lead cables and conductors securely.
• If the cables are laid loosely, use only cable entries approved for this
type of cable laying.
WARNING
Danger of electric shock due to energised parts!
Non-compliance can result in severe or fatal injuries.
• All connections and wiring must be disconnected from the power supply.
• Secure the connections against unauthorized switching.
Ex e terminal compartment.
To prevent condensation in the enclosure, we recommend using a breather,
type 8162 by R. STAHL Schaltgeräte GmbH.
By using a breather and depending on its mounting position, the degree of
protection acc. to IEC 60529 is reduced. If mounted lateral, the degree
of protection is IP64, if opening of breather is installed downwards, it is IP56.
≦ 90°