Operation
16
214040 / 6521613300
2020-07-27·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Floodlight
Series 6521/5
9
Operation
9.1
Troubleshooting
Refer to the following troubleshooting chart during troubleshooting:
If the error cannot be eliminated using the mentioned procedures:
• Contact R. STAHL Schaltgeräte GmbH.
For fast processing, have the following information ready:
• Type and serial number of the device
• Purchase information
• Error description
• Intended use (in particular input / output wiring)
10
Maintenance, Overhaul, Repair
Cause of error
Troubleshooting
The lamp was incorrectly inserted.
Insert the lamp correctly.
The lamp is defective.
Replace the lamp.
The control gear is defective.
Replace the control gear.
DANGER
Explosion hazard due to hot built-in components!
Non-compliance results in severe or fatal injuries.
• Only open the enclosure in switched-off state.
• The device (with HST 250 W) must be allowed to cool down for at least
15 minutes before opening it.
• The device (with HST 400 W) must be allowed to cool down for at least
30 minutes before opening it.
CAUTION
Risk of electric shock or malfunction of the device due to unauthorized work!
Non-compliance can result in light injuries!
• Before carrying out work on the device, switch off voltage supply.
• Work performed on the device must only be carried out by authorized
and appropriately trained qualified electricians.