264820 / 6050628300
2018-07-24·BA00·III·en·01
Maintenance, Overhaul, Repair
17
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Universal spotlight LED
Series 6050/6
9
Maintenance, Overhaul, Repair
9.1
Maintenance
• Refer to the relevant national regulations to determine the type and extent of
inspections.
• Adapt inspection intervals to the operating conditions.
At a minimum, check the following points during maintenance work on the device:
• Proper function of glass dome and housing,
• Condition of the connection lines,
• Connection of the protective conductor and equipotential bonding,
• Proper function and secure fit of cable entries,
• Seals within the cable entries,
• Cleanliness and proper function of the housing interiors (Ex d and Ex e),
• Secure fit of the holding bracket mounting screws,
• Good visual condition of the flameproof joint (dirt or damage)
• Comply with the permissible temperatures (according to EN 60079),
• Whether the device is used in accordance with its intended use.
9.2
Overhaul
CAUTION
Risk of electric shock or malfunction of the device due to unauthorized work!
Non-compliance can result in light injuries!
• Before carrying out work on the device, switch off voltage supply.
• Work performed on the device must only be carried out by authorized
and appropriately trained qualified electricians.
WARNING
Risk of burns due to hot surfaces!
Non-compliance can result in severe injuries and material damage.
• Allow the housing, the protective glass and the lamp cool down for
approx. 15 min before touching them.
CAUTION
Danger of electric shock due to energised parts!
Non-compliance can result in minor injuries!
• All connections must be disconnected from the power supply.
• Secure the connections against unauthorized switching.
Observe the relevant national regulations in the country of use.