Adjust the gain by dialing the rotary encoder. The gain is adjusted in steps of 0.25dB.
The DS20 inputs are fixed. Input 1 is routed from the analog XLR-input of channel 1,
Smaller steps (0.01dB) can be set via the PC or MAC interface.
channel 2 is routed from the analog XLR-input of channel 2, channel 3 and 4 are routed
from the digital AES/EBU XLR-input on the backside of the DS20.
4
4
4
4
.
.
.
.
2.
2.
2.
2.
1
2
3
4
Gain
Input Selection
Delay
Low Pass Filter
OPERA
T
ION
stage accompany
R
DS20 USER MANUAL
4-2
EXIT
EXIT
EXIT
EXIT
EXIT
MENU
MENU
MENU
MENU
MENU
SELECT
SELECT
SELECT
SELECT
SELECT
In 1 Gain
In 1 Delay
In 1 LowPass
In 1 LowPass
In 1 LowPass
0dB
1.020ms
Freq: 14500Hz
Enabled: On
Type: BUT 24dB
Set the delay time by turning the encoder. The delay time on the front will be shown in ms, by
Adjust the Low Pass Filter frequency by turning the rotary encoder. You can switch the low
pass filter off by turning the rotary encoder up (clockwise) until the frequency passes 20kHz.
Press the rotary encoder to change the filter type. Selct the type by turning the rotary encoder.
You can choose from: Butterworth 6dB, Bessel 6dB, Butterworth 12dB, Bessel 12dB, Linkwitz
Riley 12dB, Butterworth 18dB, Bessel 18dB, Butterworth 24dB, Bessel 24dB. Higher order
filters may be set by adding filter sections in the PEQ blocks (see below).
Enable or disable the Low Pass filter by rotating the encoder between on and off.
controlling the DS20 with Stage Control the displayed unit can be changed between ms or s,
mm or m, feet, inches, or mils.