background image

Page

 

 

 

 

 

       

ST316B User Handbook

 

14

 

Adjusting While Firing

 

Firing values can be adjusted while the ST316B is firing.  Also there are 

program pause/un

-

pause and segment advance features that are particular-

ly useful for glass work.

 

Adjusting Firing Values

 

While firing operate the 

 key to select the required parameter as shown by 

a flashing lamp on the mimic display.  The firing value is shown on the main 
display and can now be adjusted with the 

 & 

 keys in the usual way.  The 

contents of the current segment or any segment still to be executed can be 

changed.  Firing will still carry on as normal while these changes are being 

made.  The ST316B will return to its normal running display 10 seconds 
after key presses cease (or immediately after 



 is displayed).

 

 

Changes made to programs in this way are stored and are used for 

subsequent firings.

 

Segment Advance Facility

 

While firing press and hold down the  

 key for about 4 seconds.  The 

ST316B will sound a short beep and the executing program will immedi-

ately advance one step as indicated by lamps on the mimic panel.  The 

effect of this is as follows:

 

If a start delay is currently executing then the ST316B will terminate this 

and start firing immediately.

 

 

If ramp 1 is currently executing then the ST316B will switch to ramp 2 

using ramp rate 2 from the current kiln temperature.

 

 

If ramp 2 is currently executing then the ST316B will switch to soak at the 

current kiln temperature.

 

 

If currently soaking then the ST316B will advance to the next segment if 

any, or else it will end the firing.

 

 

Changes made to the operation of the ST316B in this way are temporary 

and are not stored.

 

Ad

just

ing 

Whil

e Firing

 

Содержание ST316B

Страница 1: ... User Handbook Page 1 ST316B User Handbook ST316B Temperature Programmer TAFFOR S D Issue 3 00 Date 05 Jan 2021 See separate handbook for Installation Instructions Copyright 2009 2021 Stafford Instruments Ltd ...

Страница 2: ...6B User Handbook 2 MAIN DISPLAY SEGMENT MIMIC DISPLAY DISPLAY INDICATORS CONTROL KEYS 5 At A Glance DELAYED START LAMP t1 LAMP SOAK TIME LAMP SOAK TEMPERATURE LAMP RAMP 1 LAMP RAMP 2 LAMP At A Glance FIRING LAMP ...

Страница 3: ... press the key to enter the programming menu To change firing data press the keys to change the displayed value Use the key again as necessary to index to the next firing value or segment to be reviewed or changed To mark the end of a program set a ramp rate to with the key To exit the programming menu either wait 10 sec onds or press the START STOP key to start firing If the keyboard is locked th...

Страница 4: ... programs each with up to 9 segments 2 controlled heating cooling ramps soak per segment Soak times up to 99 hours 59 mins Ramp rates from 1 to 999 C hour full Suitable for ceramics and glass use Programs can be altered while firing Program pause un pause segment advance facilities Keyboard lockable Delayed start facility up to 99 hours 59 mins Power failure recovery Energy used display Alarm buzz...

Страница 5: ...the type of thermocouple fitted to the kiln and can be R S K or N type R type thermo couple S type thermo couple K type thermo couple N type thermo couple C C hr hr min C C hr hr min C C hr hr min The final display should show the kiln temperature 20 C shown here with the C indicator on All oth er lamps should be off If the left hand decimal point is on then the keyboard is locked This is an anti ...

Страница 6: ...mp rate 2 It then soaks dwells at the soak temperature for the soak time It then runs the next segment until the end of the pro gram is reached The ST316B is capable of both positive heating ramps and negative cooling ramps as used in glassmaking for annealing Ramp rate 1 ramp rate 2 are settable in the range 1 C hour to 999 C hour or full power or end of program t1 the soak temperature are settab...

Страница 7: ... of the key displays the start delay time in the range 00 00 to 99 59 99 hours 59 mins This can be altered with the keys The DELAYED START lamp on the mimic display will flash C C hr hr min then displays ramp rate 1 in the range 1 to 999 C hr or or This can be altered with the keys RAMP 1 lamp on the mimic display will flash C C hr hr min then displays temperature t1 in the range 0 to 1400 C This ...

Страница 8: ...ediately Programming A further push of the key increments the segment display digit and firing data for the next segment can be entered SEGMENT C C hr hr min Data entry is terminated if is selected with the key for either ramp rate 1 or ramp rate 2 Data entry is also automatically terminated if 9 segments have been entered Note the key can be used to reverse through the programming steps to correc...

Страница 9: ...ll light If kiln heating is re quired then the right hand decimal point on the display will light while heating power is being applied to the kiln Information The ST316B operates by calculating the amount of energy required by the kiln every 30 seconds installer adjustable If for example 40 of full energy is required to maintain a particular ramp rate or a particular soak temperature then the ST31...

Страница 10: ...Page ST316B User Handbook 10 Program Record Sheet Segment No Ramp 1 C hr t1 C Ramp 2 C hr Soak Temp C Soak hr Please photocopy me ...

Страница 11: ...ST316B User Handbook Page 11 k Time min Notes Please photocopy me Program No ...

Страница 12: ... firing then the firing will be halted not paused Pressing the START STOP key again will cause the ST316 to restart the firing from the beginning The ST316B will look at the current kiln temperature and if this is greater than temperature t1 then the ST316B will automatically cool from current temperature to t1 at ramp rate 1 This may not be what is desired so the STOP key should only be used to h...

Страница 13: ...hr min C C hr hr min While the kiln temperature is above 40 C the display alternates every 5 seconds between the kiln temperature and When the kiln has cooled to less than 40 C the display alternates every 5 seconds between the kiln temperature and To return the ST316B back to idle condition ready for the next firing press the START STOP key or turn off the power to the instrument Cooling ...

Страница 14: ...iately after is displayed Changes made to programs in this way are stored and are used for subsequent firings Segment Advance Facility While firing press and hold down the key for about 4 seconds The ST316B will sound a short beep and the executing program will immedi ately advance one step as indicated by lamps on the mimic panel The effect of this is as follows If a start delay is currently exec...

Страница 15: ... resumed when un pause is se lected Segment advance key held down for about 4 seconds can also be used to terminate the pause This will advance the segment and will immedi ately terminate a paused soak advancing to the next segment if any Changes made to the operation of the ST316B in this way are temporary and are not stored C C hr hr min As a warning during pause a double beep is sounded every 1...

Страница 16: ... The kiln has been on zero power for 30 minutes but the kiln temperature has not fallen by at least 1 C C C hr hr min C C hr hr min C C hr hr min C C hr hr min Possible causes are kiln door or lid not closed properly heater element failure elements too old power phase failure contactor failure or thermocouple short circuit Error 5 Kiln temperature overshoot The kiln temperature exceeds the desired...

Страница 17: ...iary alarm relay if fitted to open see installation handbook for details Note these error messages are provided to detect kiln faults and so offer some protection to the kiln For increased protection the use of a heat fuse or other independent over temperature trip is recommended such as the Stafford Instruments ST121 Error 7 Maximum room temperature exceeded The internal temperature of the ST316B...

Страница 18: ... firing or while it is firing It cannot be locked while it is being programmed If the left hand decimal point in the dis play is lit then the ST316B is locked Press and hold in both the keys for 5 seconds to unlock the ST316B C C hr hr min If the left hand decimal point in the display is not lit then the ST316B is not locked Press and hold in both the keys for 5 seconds to lock the ST316B Power Fa...

Страница 19: ... C 00 30 FULL 1040 C Earthenware High Temperature Glaze 90 C hr 600 C 00 30 FULL 1140 C Stoneware Glaze 90 C hr 600 C 00 30 FULL 1250 C On Glaze Enamel 90 C hr 600 C 00 30 FULL 780 C Heavy Sculpture 50 C hr 300 C 00 30 70 C hr 1000 C Lustre 90 C hr 600 C 00 00 FULL 750 C Sample Programs Notes Earthenware High Temperature Glaze is also suitable for Stoneware Low Temperature Glaze Stoneware Glaze is...

Страница 20: ...Page ST316B User Handbook 20 www staffordinstruments co uk Supplied by ...

Отзывы: