Stafer V6S-27/13 Скачать руководство пользователя страница 4

02

04. FITTING THE ADAPTORS

1) Fit the adaptor ring and, centring the insertion key, push it to the bottom of the base ring.
2) Fit the drive pulley, so the clips coincide with the hooking teeth of the pinion until a “click” is heard.

05. ALCUNE INFORMAZIONI SUL FUNZIONAMENTO DEL MOTORE

05.1 

Warnings

05.2 Power supply

05.3 Command buttons

The buttons have to be applied to the wires BLACK and BROWN and must close on the BLUE wire (neutral).  

You must use buttons with spring return (“hold to run” type)

, do not 

use buttons with maintained position. More command buttons can be connected via a parallel connection. The control buttons are subject to the mains voltage and therefore should be 
properly insulated and protected.

05. ELECTRICAL CONNECTION

The end-strokes are integrated in the motor. They restrict the stroke of the shutter, awning, etc. 
with at most 28 turns. Their correct adjustment is necessary to ensure perfect and lasting operation
 both of the motor and the driven part installed. The factory setting allows about 3 turns for each direction of 
operation.

Roller shutter / garage door

Mind the moving rolling shutter and keep away until the shutter is completely lowered.

Figure 1: motor installed on right (seen from inside)
           A. high end-stroke 
           B. low end stroke
 
Figure 2: motor installed on left (seen from inside)
           C. high end-stroke 
           D. low end-stroke 

Do not use manual safety bolts on the roller shutters (when this motor is installed)

06. SETTING THE END-STROKE POSITIONS

All rights reserved. 
STAFER S.p.a. - via Malpighi, 9 - 48018 Faenza (RA) ITALY
Tel. (+39) 0546.624811 - Fax. (+39) 0546.623141 - www.stafer.com

WIRING
INSIDE
MOTOR

The installation must be performed by a qualified technician. 
If in doubt contact your supplier.

Main power

supply

Make connections with  power supply disconnected.

 Check that the power supply line doesn't depend from electrical circuits for lighting.

 The supply line must be equipped with a 

circuit breaker. The installer must to fit an isolation device (with 3,5 mm minimum opening on the contacts) upstream of the system.

 The section of the connecting cables must be 

proportionate to their length and to the absorption of the load, and in any case not less than 1.5 mm. 

 The productdoesn't provide any protection against overloads or short circuits. 

You must provide, on the supply line, an adequate protection to the load , for example a rapid fuse of maximum value 3.15 A. 

  You must use buttons with spring return ("hold-to-run" 

type), do not use buttons with maintained position. 

 Command buttons are connected to the main voltage, so they must be properly insulated and protected. 

 Isolate the gray wire 

until you have completed the connections. 

 If you do not want to use the function of "motor release" isolate and do not connect the gray wire. 

  Use a 6V battery. Simply 1,5 Ah. 

  

Connect the battery to a battery charger suitable plugged. 

  Periodically check the efficiency of the battery. Refer to the product warranty. Replace it if necessary with equivalent 

battery. 

  Protect the battery circuit with a 1A fuse.

The supply voltage must be applied to the blue (NEUTRAL) wires and brown/black to drive up/down . Connect the green / yellow wire to the grounding system.
The electrical specifications for motor operation are shown in the label applied to the tube of the motor.

All products and technical specifications given in this document are subject to variation without notice. Unless previously and specifically authorised by STAFER, the device must be 
used exclusively with transmitters produced by  STAFER. 
STAFER cannot be consider responsible for damage caused by improper, incorrect or unreasonable uses.

V7

S

A=end-stroke adjustment screws / B=base ring / C=insertion key / D=adaptor ring / E=exit pinion
F=drive pulley / G=washer / H=blocking screw / I=motor body / J=technical data plate
K=supply cable
 

Torque 

Nm

Rpm

Power 

W

V7

S

-80/12

80

12

375

V7

S

-100/12

100

12

410

V7

S

-130/9

130

9

410

Model

MANUAL 

COMMAND

Buttons  with 

spring return

(“hold to run” type)

RELEASE 

COMMAND

double pole

key switch

brown

blue

yellow/green

black

gray

L (phase)

N (neutral)

cable 

motor

 

BA

TTERY

FUSE 1A

N.C.

COMMON

N.O.

RELAY 10A

+

-

BATTERY

CHARGER

Содержание V6S-27/13

Страница 1: ...a riportati sul motore Con il V6S utilizzare rulli avvolgitori di spessore 10 10 con il V7S utilizzare rulli di spessore minimo 11 10 Lasciare 1 2 mm di gioco destra sinistra sul rullo avvolgitore Verificare che la puleggia di traino e la corona adattatore siano di forma e dimensioni conformi al rullo avvolgitore utilizzato Adattatori supporti e accessori vari inerenti al motore devono essere scelt...

Страница 2: ...i a posizioni momentanee a uomo presente non utilizzare deviatori a posizione mantenuta I pulsanti di comando sono sottoposti alla tensione di rete e dovranno quindi essere adeguatamente isolati e protetti E vietato collegare in parallelo 2 o più motori allo stesso pulsante di comando farlo solo con opportune centraline L fase N neutro marrone blu giallo verde nero ALIMENTAZIONE DI RETE cavo motor...

Страница 3: ...o complete the installation must not come into contact with the motor The power of the motor must be sufficient for the applied load check the rated data shown on the motor Some stages of programming and or normal operation make use of the mechanical stops of the roller shutter awning It is essential to choose a motor with the most suitable torque for the application considering the actual traction ...

Страница 4: ... isolation device with 3 5 mm minimum opening on the contacts upstream of the system The section of the connecting cables must be proportionate to their length and to the absorption of the load and in any case not less than 1 5 mm The productdoesn t provide any protection against overloads or short circuits You must provide on the supply line an adequate protection to the load for example a rapid ...

Страница 5: ...t être de la puissance adaptée à la charge appliquée vérifier les données de la plaque signalétique apposée sur le moteur Certaines phases de programmation et ou de fonctionnement normal utilisent les arrêts mécaniques du volet roulant Il est indispensable de choisir le moteur avec le couple le plus adapté à l application en tenant compte de la traction effective du volet roulant et en évitant les m...

Страница 6: ...s à positions momentanées à homme présent ne pas utiliser de déflecteurs à position maintenue Les boutons de commande sont branchés à la tension de secteur et doivent donc être bien isolés et protégés Et interdit de se connecter en parallèle 2 ou plusieurs moteurs à la même bouton de commande faire uniquement avec les unités appropriées brun bleu noir ALIMENTATION DE SECTEUR COMMANDE MANUELLE oblig...

Отзывы: