02
04. FITTING THE ADAPTORS
1) Fit the adaptor ring and, centring the insertion key, push it to the bottom of the base ring.
2) Fit the drive pulley, so the clips coincide with the hooking teeth of the pinion until a “click” is heard.
05. ALCUNE INFORMAZIONI SUL FUNZIONAMENTO DEL MOTORE
05.1
Warnings
05.2 Power supply
05.3 Command buttons
The buttons have to be applied to the wires BLACK and BROWN and must close on the BLUE wire (neutral).
You must use buttons with spring return (“hold to run” type)
, do not
use buttons with maintained position. More command buttons can be connected via a parallel connection. The control buttons are subject to the mains voltage and therefore should be
properly insulated and protected.
05. ELECTRICAL CONNECTION
The end-strokes are integrated in the motor. They restrict the stroke of the shutter, awning, etc.
with at most 28 turns. Their correct adjustment is necessary to ensure perfect and lasting operation
both of the motor and the driven part installed. The factory setting allows about 3 turns for each direction of
operation.
Roller shutter / garage door
Mind the moving rolling shutter and keep away until the shutter is completely lowered.
Figure 1: motor installed on right (seen from inside)
A. high end-stroke
B. low end stroke
Figure 2: motor installed on left (seen from inside)
C. high end-stroke
D. low end-stroke
Do not use manual safety bolts on the roller shutters (when this motor is installed)
06. SETTING THE END-STROKE POSITIONS
All rights reserved.
STAFER S.p.a. - via Malpighi, 9 - 48018 Faenza (RA) ITALY
Tel. (+39) 0546.624811 - Fax. (+39) 0546.623141 - www.stafer.com
WIRING
INSIDE
MOTOR
The installation must be performed by a qualified technician.
If in doubt contact your supplier.
Main power
supply
Make connections with power supply disconnected.
●
Check that the power supply line doesn't depend from electrical circuits for lighting.
●
The supply line must be equipped with a
circuit breaker. The installer must to fit an isolation device (with 3,5 mm minimum opening on the contacts) upstream of the system.
●
The section of the connecting cables must be
proportionate to their length and to the absorption of the load, and in any case not less than 1.5 mm.
●
The productdoesn't provide any protection against overloads or short circuits.
You must provide, on the supply line, an adequate protection to the load , for example a rapid fuse of maximum value 3.15 A.
●
You must use buttons with spring return ("hold-to-run"
type), do not use buttons with maintained position.
●
Command buttons are connected to the main voltage, so they must be properly insulated and protected.
●
Isolate the gray wire
until you have completed the connections.
●
If you do not want to use the function of "motor release" isolate and do not connect the gray wire.
●
Use a 6V battery. Simply 1,5 Ah.
●
Connect the battery to a battery charger suitable plugged.
●
Periodically check the efficiency of the battery. Refer to the product warranty. Replace it if necessary with equivalent
battery.
●
Protect the battery circuit with a 1A fuse.
The supply voltage must be applied to the blue (NEUTRAL) wires and brown/black to drive up/down . Connect the green / yellow wire to the grounding system.
The electrical specifications for motor operation are shown in the label applied to the tube of the motor.
All products and technical specifications given in this document are subject to variation without notice. Unless previously and specifically authorised by STAFER, the device must be
used exclusively with transmitters produced by STAFER.
STAFER cannot be consider responsible for damage caused by improper, incorrect or unreasonable uses.
V7
S
A=end-stroke adjustment screws / B=base ring / C=insertion key / D=adaptor ring / E=exit pinion
F=drive pulley / G=washer / H=blocking screw / I=motor body / J=technical data plate
K=supply cable
Torque
Nm
Rpm
Power
W
V7
S
-80/12
80
12
375
V7
S
-100/12
100
12
410
V7
S
-130/9
130
9
410
Model
MANUAL
COMMAND
Buttons with
spring return
(“hold to run” type)
RELEASE
COMMAND
double pole
key switch
brown
blue
yellow/green
black
gray
L (phase)
N (neutral)
cable
motor
BA
TTERY
FUSE 1A
N.C.
COMMON
N.O.
RELAY 10A
+
-
BATTERY
CHARGER