background image

07

11. FACTORY VALUE RESET

The motor performs two 

brief upward movements 

to indicate that it was 

reset.

H

All rights reserved. 
STAFER S.p.a. - via Malpighi, 9 - 48018 Faenza (RA) ITALY
Tel. (+39) 0546.624811 - Fax (+39) 0546.623141 - www.stafer.com

All products and technical specifications given in this document are subject to variation without prior notice.
Unless previously and specifically authorised by STAFER, the device must be used exclusively with transmitters produced by STAFER.
STAFER cannot be considered responsible for damage caused by improper, incorrect or unreasonable uses.

2 x UP 
8 x DOWN

3 x UP 
3 x DOWN

Within 15 seconds 

press 3 times on 

UP and 3 times on 

DOWN.

C

(1)

Within 15 seconds 

press twice on UP 

and once on 

DOWN.

E

(1)

the motor performs 6 

up/down movements

OFF

ON

Switch OFF power supply for 

few seconds, then switch it 

ON again.

B

Bring the motor to the 

intermediate position.

A

The motor completes 

1 up/down movement.

D

F

When the anemometer is reset, all settings will return to factory values.

2 x UP

Within 5 seconds, 

press UP twice

G

(1)

Notes:

ü

(1) Button must be pressed shortly, approx. 1 second between two pressures.

The device is provided with a diagnosis function of the wind sensor. If, for about 24 hours the wind sensor does not generate any valid pulse, the sensor 
commands an automatic upward manoeuvre of the awning, suspends all other activities and indicates the fault by flashing the LEDs. The device will come out 
of this state resuming normal activities only when the anemometer generates a valid pulse. To exit the alarm, remove and restore power. The function cannot be 
deactivated.

09. ANEMOMETRIC TEST FUNCTION

10. ANEMOMETER CHECK ON AWNING STATUS

If the motor does not respond to the button commands, it is because some alarm has been activated. To understand the type of alarm, look at the colour of the 
LEDs under the anemometer. Alternatively, it is also possible to “ask” the anemometer about the alarm status. The device will order the motor to perform some 
movements corresponding to the active alarm. Proceed as follows.

01.  Remove and restore power.
02.  Press 

UP

 

3

 

times

 and 

DOWN 3 times

*. The motor shows: 

up/down.

03.  Press 

twice

 on 

UP

 and 5 

times

 on 

DOWN

. After 2 seconds, the 

motor provides information on the awning's current status. See 
table 3.

04.  After 5 seconds, the motor returns to its initial position.
05.  Wait for 10 seconds. The motor exits the menu without signalling.

USING THE WALL-MOUNTED BUTTON

  No. of 

movements

Alarm

2 lowering

3 x up

5 lowering

wind alarm

sun active

stopped due to 

anemometric 

test

Tab. 03 - Alarm status

Awning 

position

Closed

Open

Closed

(*) The buttons must be pressed shortly, max 1 second between two pressures.

Содержание 595.K.F2.00

Страница 1: ...www stafer com USER AND MAINTENANCE MANUAL Sun wind anemometer for 1 or 2 motors ENG 595 K F2 00 version 1 0 recycled paper ...

Страница 2: ...ith the appliance or with the fixed control devices ü Do not operate the rolling shutter when maintenance operations are being carried out e g window cleaning etc If the control device is automatic disconnect the motor from the power line 01 3 USE WARNINGS This sensor does not protect shutters in case of strong and sudden wind gusts In case of weather hazards of this type make sure that shutters r...

Страница 3: ...justed horizontally ü the bore interaxis is 25 mm ü as soon as the anemometer is powered the three coloured LEDs will briefly flash 3 times 02 02 1 LED DIAGRAM Green LED Yellow LED Red LED Close the case by tightening the screws D Unscrew the 3 screws and open the upper case A Fasten the wall support to the wall or ceiling based on your needs E Punch the rubber cable entry and insert the cable B F...

Страница 4: ...their length and to the power load absorption and in any case not less than 1 5 mm ü You must use command buttons with spring return man present type do NOTuse switches with maintained position ü Command buttons are connected to the main voltage so they must be properly insulated and protected ü Once the electrical connections are finished bring the motor motors to intermediate position and check ...

Страница 5: ...all manual commands are disabled The control unit exits the wind alarm if the wind speed keeps below the set threshold for at least 5 minutes The wind threshold ranges from 5 km h to 35 km h The factory sets the wind threshold at level 2 05 WIND SENSOR 05 1 HOW TO CHANGE THE WIND THRESHOLD Within 15 seconds press 3 times on UP and 3 times on DOWN C 1 Within 15 seconds press twice on UP and once on...

Страница 6: ...ower supply for few seconds then switch it ON again B Bring the motor to the intermediate position A The motor completes 1 up down movement D F No of movements Threshold 1 Lev 1 2 Lev 2 3 Lev 3 4 5 Lev 4 Lev 5 1 x UP To ACTIVATE the sun function G 1 x DOWN To DEACTIVATE the sun function The motor replicates the up or down movement H After 5 seconds the motor exits the menu without signal I After 5...

Страница 7: ...wer supply for few seconds then switch it ON again B Bring the motor to the intermediate position A The motor completes 1 up down movement D After 5 seconds it exits the menu I 1 UP Function active 1 DOWN Function NOT active This device provides the possibility to choose one of the following operating logics for the command buttons Pulse logic This is the default mode from the factory The motor mo...

Страница 8: ...ensor does not generate any valid pulse the sensor commands an automatic upward manoeuvre of the awning suspends all other activities and indicates the fault by flashing the LEDs The device will come out of this state resuming normal activities only when the anemometer generates a valid pulse To exit the alarm remove and restore power The function cannot be deactivated 09 ANEMOMETRIC TEST FUNCTION...

Отзывы: