ü
Incorrect installation can cause serious injuries.
ü
Keep these instructions for future maintenance operations and the disposal of the product.
ü
All the product installation, connection, programming and maintenance operations must be carried out only by a qualified and skilled technician, who must
comply with laws, provisions and local regulations, and the instructions provided herein.
ü
Wiring must comply with current CEI standards. In compliance with the provisions of Italian Ministerial Decree 37/2008, the final electrical system must be
installed only by an electrician.
ü
Some applications require “man present” operation and can exclude the use of radio commands or require particular safety devices.
ü
To prevent potentially dangerous situations, regularly check the operating condition of the rolling shutter/awning.
01.1 SAFETY WARNINGS
01. WARNINGS. WARNING!
Importanti istruzioni di sicurezza!
ü
Read the technical specifications in paragraph “Technical Specifications” to evaluate the operating parameters of the product.
ü
Before installing the product, check compatibility with associated devices and accessories.
ü
The motor connected to the device must be of the “mechanical limit switch” type, without any electronic control; the motor must be of power adequate to the
charge (check the rating plate data on the motor).
ü
Check that the package is intact and has not been damaged during transport.
ü
A heavy shock, falls, crushing and the use of unsuitable tools can cause the damage of the external or internal parts of the product.
ü
Do not pierce or tamper with the product in any way. Do not modify or replace parts without the Manufacturer's permission.
ü
Check that the location selected for product installation enables the blades to be exposed to the same wind to which the rolling shutter to be motorized is
exposed.
ü
Check that the installation location is made of solid materials and can ensure a stable installation.
ü
Do not install the product near heat sources (such as chimneys, etc....).
ü
Adjust the control unit inclination so that blades are positioned horizontally.
ü
The wind detection blades must face downward. The blades must be free to rotate without obstruction.
ü
Check that the control unit is placed in a protected position from accidental impact with other objects (e.g. branches, etc.).
ü
The power cable must be positioned in such a way as to avoid contact with moving parts.
ü
Do not use abrasive or solvent products for cleaning the device; do not clean using water-jet or high-pressure cleaners.
ü
For your safety, do not work near the coiler while the motor is powered.
01.2 INSTALLATION WARNINGS
ü
The product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are supervised or given instructions about the product way of use by a person responsible for their safety.
ü
Check automation during operation and keep people at a safe distance, until operation ends.
ü
Do not allow children to play with the appliance or with the fixed control devices.
ü
Do not operate the rolling shutter when maintenance operations are being carried out (e.g. window cleaning, etc.). If the control device is automatic,
disconnect the motor from the power line.
01.3 USE WARNINGS
This sensor does not protect shutters in case of strong and sudden wind gusts.
In case of weather hazards of this type, make sure that shutters remain closed! Stafer S.p.A.
declines all liability for damage incurred due to weather events not detected by the device.
Any other use beyond the field defined by Stafer S.p.A. is prohibited and involves, as well as the failure to comply with instructions provided in this guide,
voidance of Stafer S.p.A.'s liability and warranty. The installer, after the installation of the product, must train the end user about the use of the automation and
provide him with the User and maintenance manual.
WARNING!!
STAFER uses recyclable packaging materials. Dispose of materials in
proper containers, in compliance with laws in force in your location.
If you are an installer and use a large number of motors, ask your dealer
about receiving motors in “honeycomb pads”, an environmentally friendly
choice that limits clutter and waste by reducing the amount of packaging
materials.
This product may have substances that are polluting for the
environment and dangerous for the health. At the end of the
product life cycle, carefully comply with local waste disposal
rules. It is strictly forbidden to dispose of the product in the
domestic waste.
Let's protect the environment!
01 Warnings
page 01
02 Assembly instructions
page 02
03 Electrical connections
page 03
04 Interfacing with home automation control units
page 04
05 WIND sensor
page 04
05.1 How to change the wind threshold
05.2 Visual LED signals associated with the wind sensor
05.3 Forced exit from the wind alarm
06 SUN function
page 05
06.1 Activation/deactivation of “sun” function
06.2 How to change the sun threshold
06.3 Visual LED signals associated with the “sun” function
07 Automatic lowering function after wind alarm
page 06
08 Operating logic of command buttons
page 06
09 Anemometric test function
page 07
10 Anemometer check on awning status
page 07
11 Factory values reset
page 07
Index
ü
Power supply:
120 or 230 Vac, 50/60 Hz
ü
Dimensions:
240 x 60 x H.111/133 mm
ü
Weight:
230 g
ü
Operating temperature:
from –20 to +55 °C
ü
Protecnion degree:
IP 55
ü
Wind threshold:
from 5 to 35 km/h
ü
Sun threshold:
from 1 to 45 Klux
Technical specifications
Dear Customer, thank you for purchasing a Stafer S.p.A. product. This guide contains information about the use of the product. Before installing and using the
product, please read this guide carefully and keep it for future reference.
595.K.F2.00 is a sun/wind sensor designed to operate tubular motors with mechanical limit switch powered by main voltage, and suitable to operate awnings,
blinds or similar products. 595.K.F2.00 allows operating the automatic retraction of rolling shutters connected to the motor when the wind exceeds the set
threshold, as well as their release when the intensity of sun exceeds the set threshold. These thresholds are set by the factory, but they can be adjusted
according to the needs.
595.K.F2.00
01