Installation

For assuring the minimum coverage of your home, one smoke alarm device should be installed respectively in

the hallway/on the stairs and in every bedroom, for providing additional protection in the living room and/or rooms

equipped with electrical devices (e.g. TV or computer room).
The range of the radio signal (max. 30 m) depends above all on the constructional conditions of the building.

Each „obstacle“ in the transmission path reduces the range; some materials (e.g. metal, reinforced concrete)

give rise for considerable screening effects. Other radio systems in the immediate vicinity may also lead to

malfunctions. Thus, prior to installing the detectors, check whether a reliable radio link is assured between the

planned mounting positions! Later constructional modifications (e.g. placing of steel cabinets, mounting of internal

dividing walls) may affect the transmission path. For this reason, please check the radio link between the smoke

alarm devices once again after such measures!
If possible, always install the smoke alarm device in the middle of the ceiling. If this is not possible, make sure

to install the smoke alarm device at a minimum distance of 50 cm from the wall and of 60 cm from the corner

of the room (see diagram).

Coding

First, the DIP switch (located in the detector’s basic module) of all smoke alarm devices which are to be interlinked

must be adjusted to the same code. With three DIP switches, there are 8

possible combinations (e.g. on/on/off, off/on/off) such that 8 different codes

can be adjusted. In this way, a different code can be selected in case of

possible interferences with other radio systems in immediate vicinity or

several separated smoke alarm device groups can be set up (e.g. one

detector group per accommodation unit in multi-flat homes or terraced houses).
Use a pen or pencil to adjust the requested code.

Important note: Adjust the same code on all detectors to be interlinked! In case of an alarm, only the

detectors belonging to one group are triggered! All wireless smoke alarm devices adjusted to another

code are not activated!

Mounting

Mark the drill holes at the planned mounting position first by using the basic module as drilling jig.
Insert the 4 alkaline batteries (1.5 V, AAA) into the battery compartment of the basic module by observing the

correct polarity (+/- marking) (both LEDs briefly flash). When the green LED flashes (approx. every 35 sec.), the

basic module is operable.
Insert the 9 V block battery into the battery compartment of the smoke alarm device and attach the battery clip

to the battery.
Insert the plug of the connecting cable on the smoke alarm device into

the socket on the basic module.
Turn the smoke alarm device on the basic module, until it locks in. If

the red LED flashes (approx. every 35 sec.), the smoke alarm device

is operable.
Position all prepared radio smoke alarm devices which are to be installed

at the planned mounting positions and check afterwards (see function

test) whether a radio link is given and whether all detectors are triggered.

If required, optimize the detector distribution prior to drilling the necessary

holes for the fixing screws and to mounting the detectors at the ceiling.

ceiling

dead space

never install here

heat and smoke

of fire

best install here

60 cm min.

ON

OFF

Plug

Socket

Содержание 51114

Страница 1: ...l sst sich das Ger t drahtlos mit weiteren stabo Funk Rauchwarnmeldern vernetzen Frequenzbereich 868 MHz Registriert einer der Melder Rauchpartikel l sen alle vernetzten Melder aus und das Alarmsigna...

Страница 2: ...uchtwege fest l Erkl ren Sie vor allem Kindern und Hilfsbed rftigen was der Rauchwarnmelder Alarm bedeutet und dass sie das Haus die Wohnung im Notfall so schnell wie m glich ggf auch selbst ndig verl...

Страница 3: ...rungen mit anderen Funk Systemen in der Umgebung auf einen anderen Code ausweichen oder auch mehrere getrennte Rauchwarnmelder Gruppen einrichten z B jeweils eine Melder Gruppe pro Wohneinheit in Meh...

Страница 4: ...onsten keine Funkverbindung zu den anderen Meldern gew hrleistet ist Wenn die Batteriekapazit t des Rauchwarnmelders nachl sst ert nt ca alle 35 Sek ein Piepton Ersetzen Sie dann umgehend die 9 V Bloc...

Страница 5: ...n with other stabo wireless smoke alarm devices can be set up frequency range 868 MHz If smoke particles are detected by one of the detectors all interlinked detectors trigger an alarm such that the a...

Страница 6: ...specify two escape routes l Explain the meaning of the smoke alarm device above all to children and needy persons and tell them that in case of an emergency they have to leave the house flat as fast a...

Страница 7: ...a different code can be selected in case of possible interferences with other radio systems in immediate vicinity or several separated smoke alarm device groups can be set up e g one detector group pe...

Страница 8: ...he batteries since the radio link to the other detectors is otherwise not be assured anymore If the battery capacity of the smoke alarm device becomes weak a beep sounds approx every 35 sec In this ca...

Отзывы: