background image

If necessary, the inclinometer will also work with only one battery, but this will reduce 
the lifetime of the battery considerably! 

Please note:

 Do not leave used batteries in the inclinometer - even batteries that are 

protected against leaking might corrode and release chemicals. These chemicals might be 
dangerous to your health and damage the battery compartment.  
Used batteries have to be disposed in suitable containers. 

Cleaning:

 The inclinometer and the display windows should be cleaned with a moist 

cloth.  

Attention: Do not use solvents or diluting agents! This might harm the surface of the 
inclinometer.  

Technical data 

Operating temperature range: 

-10°C to +50°C = 14°F to 122°F

Storage temperature range: 

-20°C to +65°C = -4°F to  149°F

Measuring accuracy at 0° and 90°: 

+/-0,05° 

Measuring accuracy from 0,1° to 89,9°:  

+/-0,2° 

Power supply: 

2*1,5V Mignon (AA) Alkaline 

Operating time: 

> 150 hours (measuring cycle: 5min measuring,
instrument off for 1min, every 30th measurement
with 30 seconds illumination)

Measuring accuracy of level: 
In normal position: 

 

+/-0,029° = 0,50mm/m 

Overhead measuring:   

+/-0,029° = 0,50mm/m 

Dust and water protection: 

IP65 

Technical details subject to change without notice. 

The instrument is available in different level lengths. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание TECH 196-2 Electronic Series

Страница 1: ...sion IP65 Code International Protection Rating 6 Dust tight complete protection against dust 6 is the highest possible rating 5 Water projected by a nozzle against enclosure from any direction shall h...

Страница 2: ...caps simply press your Electronic level up against a wall or other solid vertical surface See picture Adjust your level until the bubble on the horizontal vial is exactly centered between the indicato...

Страница 3: ...s not change during calibration When movements occur during the calibrating process err is shown on the display Inclinations of more than 1 above the set 0 value are blocked The former calibration wil...

Страница 4: ...u use this multi MODE function empowers you to switch from one MODE to another to do conversions example convert inches per foot to degrees to make a cut o How to Use Simply push the Button that is la...

Страница 5: ...n will display your angle or slope for 2 seconds and then return to Reference mode To return your electronic level back to calibrated level again simply push the REF button for 3 seconds then release...

Страница 6: ...automatic shut off function into the electronic module The factory preset for the module is 10 minutes after the last movement Should you find the need to extend the auto shut off time the module can...

Страница 7: ...eaning The inclinometer and the display windows should be cleaned with a moist cloth or brush Attention Do not use solvents or diluting agents This might harm the surface of the inclinometer Changing...

Страница 8: ...ng agents This might harm the surface of the inclinometer Technical data Operating temperature range 10 C to 50 C 14 F to 122 F Storage temperature range 20 C to 65 C 4 F to 149 F Measuring accuracy a...

Отзывы: