Button Functions:
On/Off
o
This button simply powers the electronic module on and off.
CAL= Calibration
o
Explanation:
This button enables you to re-calibrate your level
at any time. Although the accuracy of this level is locked in, it is
always a good practice to check your module for accuracy as it
is with any high precision measuring instrument. If your level
has taken a fall or you just want a piece of mind; follow our
simple instructions and re-calibrate your Electronic level in less
than 7 seconds.
o
How to use:
With the patented wall gripping end caps, simply
press your Electronic level up against a wall or other solid
vertical surface. (See picture) Adjust your level until the
bubble on the horizontal vial is exactly centered between the
indicator rings. At this point, since the end caps are gripping
the wall surface, use one hand to hold the level still and with
the other hand press the CAL button once, then once again.
(this is a safety mechanism built in for accidental button
pushing) Hold still for approximately 4 seconds while the module
takes 128 measurements and locks in the new calibration. At
this point the L
C
D screen will
show ready
“RDY”
and the module
beeps
. Now your level is “ready” and
newly
calibrated.