Button Functions: 

On/Off

o

This button simply powers the electronic module on and off.

CAL= Calibration

o

Explanation: 

This button enables you to re-calibrate your level

at any time. Although the accuracy of this level is locked in, it is
always a good practice to check your module for accuracy as it
is with any high precision measuring instrument. If your level
has taken a fall or you just want a piece of mind; follow our
simple instructions and re-calibrate your Electronic level in less
than 7 seconds.

o

How to use: 

With the patented wall gripping end caps, simply

press your Electronic level up against a wall or other solid
vertical surface. (See picture) Adjust your level until the
bubble on the horizontal vial is exactly centered between the
indicator rings. At this point, since the end caps are gripping
the wall surface, use one hand to hold the level still and with
the other hand press the CAL button once, then once again.
(this is a safety mechanism built in for accidental button
pushing) Hold still for approximately 4 seconds while the module
takes 128 measurements and locks in the new calibration. At
this point the L

C

D screen will 

show ready 

“RDY”

 and the module

beeps

. Now your level is “ready” and 

newly 

calibrated.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание TECH 196-2 Electronic Series

Страница 1: ...sion IP65 Code International Protection Rating 6 Dust tight complete protection against dust 6 is the highest possible rating 5 Water projected by a nozzle against enclosure from any direction shall h...

Страница 2: ...caps simply press your Electronic level up against a wall or other solid vertical surface See picture Adjust your level until the bubble on the horizontal vial is exactly centered between the indicato...

Страница 3: ...s not change during calibration When movements occur during the calibrating process err is shown on the display Inclinations of more than 1 above the set 0 value are blocked The former calibration wil...

Страница 4: ...u use this multi MODE function empowers you to switch from one MODE to another to do conversions example convert inches per foot to degrees to make a cut o How to Use Simply push the Button that is la...

Страница 5: ...n will display your angle or slope for 2 seconds and then return to Reference mode To return your electronic level back to calibrated level again simply push the REF button for 3 seconds then release...

Страница 6: ...automatic shut off function into the electronic module The factory preset for the module is 10 minutes after the last movement Should you find the need to extend the auto shut off time the module can...

Страница 7: ...eaning The inclinometer and the display windows should be cleaned with a moist cloth or brush Attention Do not use solvents or diluting agents This might harm the surface of the inclinometer Changing...

Страница 8: ...ng agents This might harm the surface of the inclinometer Technical data Operating temperature range 10 C to 50 C 14 F to 122 F Storage temperature range 20 C to 65 C 4 F to 149 F Measuring accuracy a...

Отзывы: