background image

LAX 600 series

3

en

1. Intended use

Congratulations on the purchase of your STABILA measuring tool. 

STABILA laser units from the LAX 600 series are simple to operate laser lines with three 

360° laser lines for levelling in a horizontal and vertical direction, for transferring/creating 

90° angles and for plumb lines. 

The laser units have a sealed casing (IP 65) for use on building sites. 

They are self-levelling within a range of ±4°. 

The laser lines are pulsed, which makes it possible to work over greater distances using 

a special STABILA line receiver. For more information refer to the operating instructions 

for the line receiver.

The LAX 600 series can only be operated with a 12 V Li-Ion CAS System battery. 

LAX 600 G:

 

Receivers must be suitable for green laser beams.

These operating instructions are valid for all devices from the LAX 600 series.  

The laser beams are only displayed in one colour.

If you still have questions after reading the operating instructions,  

you can obtain advice over the phone at any time: 

+49 / 63 46 / 3 09 - 0

Equipment and functions:

•  Pulsed laser lines
•  1x 360° horizontal laser line 
•  2x 360° vertical laser lines
•  90° angle in horizontal and vertical direction
•  Plumb line laser function
•  Manual mode
•  1/4" tripod socket
•  Carrying case
•  STABILA CAS – 12 V Li-Power 2.0 Ah battery – not included in every set
•  SC 30 charger, 12-18 V, CAS system – not included in every set

LAX 600 G:

 

•  Includes green laser beams to improve visibility with the naked eye.

2.2 Safety instructions for the Li-ion battery pack

Thoroughly read the safety instructions and operating instructions for the Li-ion battery 

pack. 

2.1 Safety instructions for laser units

In Class 2 laser units, your eyes are usually protected from accidental, short-term expo-

sure to the laser beam by the eyelid-closing reflex and/or the reflex reaction to turn 

one’s head. If a laser beam hits your eye, deliberately close your eyes and move your 

head out of the path of the beam. Do not look into the direct or reflected beam.  

The STABILA laser goggles available for our laser units are not safety eyewear:  

their function is to improve the visibility of the laser beam. 

• 

Do not aim the laser beam directly at people! 

• 

Avoid dazzling other people with the unit! 

• 

Keep the unit out of the reach of children!

• 

If operating or adjustment equipment that has not been specified here is used, or 

if the unit is not operated in the ways described here, this may result in hazardous 

exposure to radiation! 

LASER

2

LASER RADIATION

DO NOT STARE INTO BEAM
510 - 635 nm / <1mW
CLASS II LASER PRODUCT

CFR 1040.10 AND CFR 1040.11

Содержание LAX 600 Series

Страница 1: ...How true pro s measure LAX 600 series Operating instructions 3x 360 LINES ...

Страница 2: ... 4 Commissioning 5 4 1 Inserting and charging the battery 5 4 2 Switching the unit on 6 4 3 Commissioning without the levelling function 6 5 Functions 7 5 1 Selecting laser functions 7 5 2 Working with the receiver 7 6 LED indicators 8 7 Using the SWB10 bracket 9 8 Checking the accuracy 10 8 1 Vertical check 10 8 2 Horizontal check 11 8 3 Angle check 12 9 Technical data 13 ...

Страница 3: ... Plumb line laser function Manual mode 1 4 tripod socket Carrying case STABILA CAS 12 V Li Power 2 0 Ah battery not included in every set SC 30 charger 12 18 V CAS system not included in every set LAX 600 G Includes green laser beams to improve visibility with the naked eye 2 2 Safety instructions for the Li ion battery pack Thoroughly read the safety instructions and operating instructions for th...

Страница 4: ...l laser line 10 Button Pulse mode for receiver operation 11 Battery 12 Battery release 13 Red button Activation of the capacity display 14 Green LED Display of charge capacity 15 Serial number 16 1 4 tripod socket 17 Casing Protected against water jets and dust in accordance with IP 65 18 SUB 10 19 1 4 connection bolt 20 Hanging hole 21 Magnet surface 22 1 4 5 8 tripod socket 23 SWB 10 24 Hanging ...

Страница 5: ...y pack must not be inserted in the charger LED display low charge capacity 20 charge the battery pack Do not allow the battery pack to become fully discharged Charging the battery pack Thoroughly read the safety instructions and operating instructions for the battery pack Release the locking device and remove the battery pack from the laser unit Insert the battery pack into the charger Connect the...

Страница 6: ...elling function Marking function mode can only be switched on with the Manual mode switch The laser beam flashes twice every 5 seconds The LAX 600 LAX 600 G is not in self levelling mode and can only be used in this mode for marking and alignment Always use the centre of the laser line when marking and aligning The laser beam flashes if the inclination of the laser unit is too steep The laser unit...

Страница 7: ...t possible to switch off all of the laser lines at the same time via the Laser lines buttons One laser line therefore always remains activated and visible All of the laser lines can only be switched off via the sliding switch or via the man button in manual mode 5 2 Working with the receiver Pulse mode must be activated for work completed over larger distances or using a suitable receiver Note The...

Страница 8: ...racy Operation activated Battery temperature 70 C 158 F Ensure the unit is in the operating temperature range Check accuracy 6 LED indicators Operation activated Unit temperature 60 C 140 F Ensure the unit is in the operating temperature range Operation activated Battery check failed Replace the battery pack Operation activated Get in touch with STABILA CAS battery charge capacity too low Insert b...

Страница 9: ...The LAX 600 LAX 600G is bolted to the retaining bracket Using the magnet surface the retaining bracket is either attached to the sliding plate on the bracket or directly to magnetic metal surfaces The bracket must roughly be aligned vertically using the adjusting screw so that the LAX 600 LAX 600G is in the self levelling range Once the clamping screw has been released the LAX 600 LAX 600G can be ...

Страница 10: ...ore than 1 mm 11 256 5 Perform this check for both vertical laser lines 8 Checking the accuracy The LAX 600 LAX 600G is designed for use on building sites and is perfectly adjusted before leaving our premises As with all precision instruments check the calibration accuracy of the unit on a regular basis Always check the unit before you start work especially if it has been exposed to heavy vibratio...

Страница 11: ...aser unit through 90 without altering the height of the laser i e do not change the tripod height Allow the unit to level itself again automatically 5 Mark the centre of the laser lines on the wall point 2 6 Repeat steps 4 and 5 twice to obtain points 3 and 4 7 If the differences between the four control points are less than 6 mm 1 4 for a distance of 10 m 32 10 the unit is within its permitted to...

Страница 12: ...gn the LAX 600 LAX 600G with point C again using the laser line 8 Precisely mark point D on the other wall or on the floor using the 90 laser line Note The distance from A to B B to C and B to D should be the same to guarantee accuracy 9 Turn the LAX 600 LAX 600 G through 90 and align the first laser line with point D 10 Mark position E on the perpendicular second laser line as close as possible t...

Страница 13: ... Levelling accuracy Laser line 0 3 mm m 3 16 over 50ft centre of laser line 90 accuracy 0 3 mm m 3 16 over 50ft Batteries 12 V 2 Ah Li ion CAS battery pack 12 V 4 Ah Li ion CAS battery pack Battery life LAX 600 28 h LAX 600G 15 h Operating temperature range 10 C to 40 C 14 F to 104 F Storage temperature range 20 C to 63 C 4 F to 145 F Subject to technical modifications When operated within the spe...

Страница 14: ......