background image

SUPERMAX

®  

VS

 

Variable Speed Pump Installation and User’s Guide

Warning Page P/N 352557  Rev. C  7/18

IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS

For Installation of Electrical Controls at Equipment Pad (ON/OFF 

Switches, Timers and Automation Load Center)

Install all electrical controls at equipment pad, such as 

on/off switches, timers, and control systems, etc. to 

allow the operation (startup, shut-down, or servicing) 

of any pump or filter so the user does not place any 

portion of his/her body over or near the pump strainer 

lid, filter lid or valve closures. This installation should 

allow the user enough space to stand clear of the filter 

and pump during system start-up, shut down or servicing of the system filter.

HAZARDOUS PRESSURE: STAND CLEAR OF 

PUMP AND FILTER DURING START UP

Circulation systems operate under high pressure. 

When any part of the circulating system (i.e. 

locking ring, pump, filter, valves, etc.) is serviced, 

air can enter the system and become pressurized. 

Pressurized air can cause the pump housing cover, filter lid, and valves 

to violently separate which can result in severe personal injury or death. 

Filter tank lid and strainer cover must be properly secured to prevent 

violent separation. Stand clear of all circulation system equipment when 

turning on or starting up pump.
Before servicing equipment, make note of the filter pressure. Be sure 

that all controls are set to ensure the system cannot inadvertently start 

during service. Turn off all power to the pump.

 

IMPORTANT: Place filter 

manual air relief valve in the open position and wait for all pressure 

in the system to be relieved. 

Before starting the system, fully open the manual air relief valve and place 

all system valves in the “open” position to allow water to flow freely from the 

tank and back to the tank. Stand clear of all equipment and start the pump.  

IMPORTANT: Do not close filter manual air relief valve until all 

pressure has been discharged from the valve and a steady stream 

of water appears. 

Observe filter pressure gauge and be sure it is not 

higher than the pre-service condition. 

General Installation Information 

•  All work must be performed by a qualified service professional, and 

must conform to all national, state, and local codes. 

•  Install to provide drainage of compartment for electrical components. 
•  These instructions contain information for a variety of pump models 

and therefore some instructions may not apply to a specific model. All 

models are intended for use in swimming pool applications. The pump 

will function correctly only if it is properly sized to the specific application 

and properly installed.

Pumps improperly sized or installed or used in 

applications other than for which the pump was 

intended can result in severe personal injury or death. These risks 

may include but not be limited to electric shock, fire, flooding, suction 

entrapment or severe injury or property damage caused by a structural 

failure of the pump or other system component.

The pump can produce high levels of suction within 

the suction side of the plumbing system. These 

high levels of suction can pose a risk if a person comes within the close 

proximity of the suction openings. A person can be seriously injured 

by this high level of vacuum or may become trapped and drown. It is 

absolutely critical that the suction plumbing be installed in accordance 

with the latest national and local codes for swimming pools.

The Virginia Graeme Baker (VGB) Pool and Spa Safety Act

 creates 

new requirements for owners and operators of commercial swimming 

pools and spas.
Commercial pools or spas constructed on or after December 19, 2008, 

shall utilize:
(A)  A multiple main drain system without isolation capability with suction 

outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings for 

Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:

(i) A safety vacuum release system (SVRS) meeting ASME/ANSI 

A112.19.17 Manufactured Safety Vacuum Release systems (SVRS) 

for Residential and Commercial Swimming Pool, Spa, Hot Tub, 

and Wading Pool Suction Systems and/or ASTM F2387 Standard 

Specification for Manufactured Safety Vacuum Release Systems 

(SVRS) for Swimming pools, Spas and Hot Tubs or
(ii) A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-off system. 

Commercial pools and spas constructed prior to December 19, 2008, 

with a single submerged suction outlet shall use a suction outlet cover 

that meets ASME/ANSI A112.19.8a and either:

(A)  A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
(B) A properly designed and tested suction-limiting vent system, or
(C) An automatic pump shut-off system, or
(D) Disabled submerged outlets, or
(E) Suction outlets shall be reconfigured into return inlets.

Mechanical Entrapment: 

 When jewelry, swimsuit, hair decorations, finger, 

toe or knuckle is caught in an opening of an outlet or drain cover.  This 

hazard is present when the drain cover is missing, broken, loose, cracked, 

or not properly secured.

NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN 

ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES, 

STANDARDS AND GUIDELINES.

TO MINIMIZE THE RISK OF INJURY DUE TO 

SUCTION ENTRAPMENT HAZARD:

•  A properly installed and secured ANSI/ASME A112.19.8 approved 

anti-entrapment suction cover must be used for each drain.

•  Each suction cover must be installed at least three (3’) feet apart, as 

measured from the nearest point to nearest point.

•  Regularly inspect all covers for cracks, damage and advanced 

weathering.

•  If a cover becomes loose, cracked, damaged, broken or is missing, 

replace with an appropriate certified cover.

•  Replace drain covers as necessary. Drain covers deteriorate over 

time due to exposure to sunlight and weather.

•  Avoid getting hair, limbs or body in close proximity to any suction 

cover, pool drain or outlet.

•  Disable suction outlets or reconfigure into return inlets.

A clearly labeled emergency shut-off switch for the 

pump must be in an easily accessible, obvious place.  

Make sure users know where it is and how to use it in case of emergency. 

Warnings and safety instructions for Pentair Aquatic Systems pumps 

and other related products are available at:

http://www.pentairpool.com/pool-owner/safety-warnings/

 or call 

(800) 831-7133 for additional free copies of these instructions.

Please refer to 

http://www.pentairpool.com/pool-owner/safety-

warnings/ 

for warning and safety instructions related to the this 

product.

Pumps and replacement motors that are single speed and 

one (1) Total HP or greater cannot be sold, offered for sale, or 

installed in a residential pool for filtration use in California, Title 

20 CCR sections 1601-1609.

iii

Содержание SUPERMAX VS

Страница 1: ...SUPERMAX VS VARIABLE SPEED PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Страница 2: ...Operating the Pump Setting the Clock Using the Default Schedule Custom Schedules Speed Priorities Non External Control Operating the Pump While Running Quick Clean Priming Quick Clean Keypad Lockout F...

Страница 3: ...AND ALL INSTRUCTIONS IN THE OWNER S MANUAL BEFORE USING THIS PUMP THESE WARNINGS AND THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAINANDAWAYFROMAL...

Страница 4: ...sly injured by this high level of vacuum or may become trapped and drown It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swi...

Страница 5: ...ow voltage digital inputs from external controls SuperMax VS Pump Controller Overview The SuperMax VS Variable Speed Pump uses a premium efficiency variable speed motor that provides tremendous progra...

Страница 6: ...uminated the pump is unable to run from any type of input 4 Display Mode LED Indicators An illuminated LED indicates the information being displayed on the screen at any specific point A flashing LED...

Страница 7: ...a as possible To reduce friction loss and improve efficiency use short direct suction and return piping 2 Install a minimum of 5 feet 1 52 meters from the inside wall of the pool and spa Canadian inst...

Страница 8: ...r stranded wire There are also fast on type quick connectors however check the local electrical codes for the desired connection method The connections must be permanently made to the grounding termin...

Страница 9: ...ing the 5V signal supplied by the drive the speeds should be wired as shown in Figure 4 When there is a low voltage signal present on the Speed Digital Input line the pump will run the speed that is p...

Страница 10: ...ure 6 Activating External Control Only EXTERNAL LOW VOLTAGE SUPPLY 5 30 V AC DC GROUND RED 5V OUTPUT FOR D I TRIGGER GREEN SPEED 1 DIGITAL INPUT YELLOW SPEED 2 DIGITAL INPUT ORANGE SPEED 3 DIGITAL INP...

Страница 11: ...the time is reset the clock will stop blinking Note When power is returned to the pump after a prolonged outage 24 hours the clock will automatically set itself to the Speed 1 start time blink and adv...

Страница 12: ...rs and minutes Note The duration parameter is adjusted in 15 minute increments 8 Pressing the 1 button will continue to cycle through these parameters but the changes are immediately saved as they are...

Страница 13: ...within 10 seconds If Quick Clean is running and you wish to stop the Quick Clean prior to the duration being completed you can press and hold the Quick Clean button for 3 seconds and the pump will re...

Страница 14: ...mperature atmospheric pressure and your pool s water level All of these things should be taken into consideration when setting the priming speed however in most cases the pump will not need to run at...

Страница 15: ...r more than three 3 seconds will cancel Quick Clean mode Note During the Quick Clean mode the pump will not start with the priming sequence Note It is recommended that you do not set the Quick Clean d...

Страница 16: ...ressing the 1 2 3 and Quick Clean buttons and cycling through all the screens Also write down the Priming Speed 3 Press and hold the 1 2 3 and Quick Clean buttons for 3 seconds 4 The screen will displ...

Страница 17: ...onsible for determining when freezing conditions may occur If freezing conditions are expected take the following steps to reduce the risk of freeze damage Freeze damage is not covered under warranty...

Страница 18: ...ure is cool to touch then open with extreme caution Be sure not to scratch or mar the polished shaft seal faces seal will leak if faces are damaged The polished and lapped faces of the seal could be d...

Страница 19: ...he ceramic face of the stationary seat Press the seal into the seal plate with your thumbs and wipe off the ceramic with a clean cloth 4 Screw impeller onto the motor shaft clockwise to tighten 5 Scre...

Страница 20: ...is in place Check water level to be sure skimmer is not drawing air Turn off electrical power to the pump Disassemble see page 14 Pump Disassembly Clean debris from impeller If debris cannot be remove...

Страница 21: ...disassembling the pump 0F Absolute AC Under Voltage Detected This indicates that the supply voltage has dropped below the operating range of 99v This could be caused by normal voltage variation and wi...

Страница 22: ...31 Diffuser Seal Mfg after 6 17 19 10 351094 Base 11 357161 Drain Plug 12 192115 O ring Drain Plug 13 351089 Volute 14 357255 O ring Lid Item Part Description 15 355667 Strainer Basket 16 350091 Lid 1...

Страница 23: ...C 12 24V DC 20 Maximum Continuous Load 2 2 THP 115 volt WEF 7 3 THP 2 2 230 volt WEF 6 6 THP 2 2 Speed Range 300 3450 RPM Environmental Rating NEMA Type 3 Ambient Conditions Storage 40 C to 85 C 40 F...

Страница 24: ...rands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those na...

Страница 25: ...SUPERMAX VS POMPE VITESSE VARIABLE CONSIGNES DE S CURIT IMPORTANTES LIRE ET SUIVRE TOUTES LES DIRECTIVES CONSERVER CES DIRECTIVES GUIDE D INSTALLATION ET D UTILISATION...

Страница 26: ...ntr le externe uniquement Fonctionnement de la pompe R glage de l horloge Utilisation du programme horaire par d faut Programmes horaires personnalis s Priorit s de vitesse Contr le non externe Gestio...

Страница 27: ...u des dommages mat riels cons quents s ils sont ignor s Avertissement sur des dangers qui pourraient causer la mort des blessures graves ou des dommages mat riels cons quents s ils sont ignor s Averti...

Страница 28: ...rcle devient mobile f l endommag bris ou est absent le remplacer par un couvercle de rechange adapt Remplacer les couvercles de drainage au besoin Les couvercles de drainage se d t riorent long terme...

Страница 29: ...ontr les externes Pompe SuperMax VS Aper u du r gulateur La pompe SuperMax VS vitesse variable utilise un moteur vitesse variable rendement sup rieur qui offre une fantastique flexibilit de programme...

Страница 30: ...t e et que la DEL n est pas allum e la pompe est incapable de fonctionner peu importe le type d entr e 4 Indicateurs DEL de mode d affichage Une DEL allum e indique l information affich e sur l cran t...

Страница 31: ...pe peut tre isol e au cours de l entretien de routine Cependant nous recommandons aussi qu une vanne un coude ou t install dans le tuyau d aspiration doit tre au moins l avant de la pompe cinq 5 fois...

Страница 32: ...es sont utilis es pour les c blages lectriques de haute tension La transmission fonctionnera sur des syst mes lectriques biphas s ligne ligne terre ainsi que sur des syst mes ligne neutre terre Cette...

Страница 33: ...fourni par la transmission est utilis les vitesses doivent tre c bl es comme le montre l Illustration 4 Lorsqu un signal de basse tension est pr sent sur la ligne d entr e num rique de vitesse la pom...

Страница 34: ...IE 5 V POUR AMOR AGE AUTOMATIQUE VERT ENTR E NUM RIQUE VITESSE 1 JAUNE ENTR E NUM RIQUE VITESSE 2 ORANGE ENTR E NUM RIQUE VITESSE 3 BRUN ENTR E NUM RIQUE VITESSE 4 NOIR MISE LA TERRE Illustration 5 Sc...

Страница 35: ...r initialis e l horloge cesse de clignoter Remarque Lorsque la pompe est nouveau aliment e en courant apr s une coupure prolong e plus de 24 heures l horloge se r gle automatiquement l heure de d mar...

Страница 36: ...de dur e peut tre r gl par paliers de 15 minutes 8 Le fait d appuyer sur le bouton 1 permet de continuer naviguer parmi ces param tres mais les changements sont automatiquement sauvegard s au fur et m...

Страница 37: ...le mode de modification si aucun autre bouton n est touch dans les 10 secondes qui suivent Si le mode de nettoyage rapide est en marche et que vous souhaitez l arr ter avant la fin de la p riode r gl...

Страница 38: ...ique et le niveau d eau de la piscine Tous ces l ments doivent tre pris en consid ration lors du r glage de la vitesse d amor age Cependant dans la plupart des cas la pompe n aura pas besoin de foncti...

Страница 39: ...e nettoyage rapide Remarque Au cours du mode de nettoyage rapide la pompe ne d marre pas avec la s quence d amor age Remarque Il est recommand de ne pas r gler la dur e du mode de nettoyage rapide 0 h...

Страница 40: ...Quick Clean Nettoyage rapide ou en navigant parmi tous les crans Il convient galement de noter la vitesse d amor age 3 Maintenir enfonc s les boutons 1 2 3 et Quick Clean Nettoyage rapide pendant 3 se...

Страница 41: ...sont pr vues suivre les tapes ci dessous afin de r duire le risque de dommages caus s par le gel Le bris en cas de gel n est pas couvert par la garantie Pour viter les dommages caus s par le gel suivr...

Страница 42: ...sente un filetage gauche et se desserre selon le sens horaire 7 Pour d visser la turbine de l arbre ins rer une cl Allen de po dans le centre du couvercle du ventilateur du moteur et tourner la turbin...

Страница 43: ...du logement fixe Appuyer le joint contre le panneau d tanch it avec les pouces et nettoyer la c ramique l aide d un chiffon propre 4 Visser la turbine sur l arbre du moteur selon le sens horaire pour...

Страница 44: ...Le filtre de la pompe est obstru V rifier les conduits d aspiration et les presse toupe des valves sur tous les robinets vanne d aspiration Fixer le couvercle sur le filtre de la pompe et s assurer q...

Страница 45: ...s internes Ces erreurs peuvent se produire en fonction des conditions de fonctionnement et du logiciel de s curit d autodiagnostic UL 60730 requis Si elles sont toujours pr sentes apr s plusieurs tent...

Страница 46: ...USEUR fabriqu apr s 6 17 19 10 351094 BASE 11 357161 BOUCHON DE VIDANGE 12 192115 JOINT TORIQUE BOUCHON DE VIDANGE 13 351089 VOLUTE 14 357255 JOINT TORIQUE COUVERCLE 15 355667 PANIER 16 350091 COUVERC...

Страница 47: ...harge continu maximum 2 2 THP 115 volts WEF 7 3 THP 2 2 230 volts WEF 6 6 THP 2 2 Plage de vitesses 300 3 450 tr min Classement environnemental NEMA Type 3 Conditions ambiantes Entreposage de 40 C 85...

Страница 48: ...ication express ment contraire les noms et les marques de tiers qui peuvent tre utilis s dans le pr sent document ne sont pas utilis s pour indiquer une affiliation ou une approbation entre les propri...

Страница 49: ...SUPERMAX VS BOMBA DE VELOCIDAD VARIABLE INSTRUCCIONES DE SEGURIDAD IMPORTANTES LEA Y SIGA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES GU A DE INSTALACI N Y DEL USUARIO...

Страница 50: ...para control digital Modo External Control Only Solo control externo Funcionamiento de la bomba Configurar el reloj Usar el programa predeterminado Programas personalizados Prioridades de velocidad s...

Страница 51: ...S INSTRUCCIONES EN EL MANUAL DEL USUARIO ANTES DE USAR ESTA BOMBA ESTAS ADVERTENCIAS Y EL MANUAL DEL USUARIO DEBEN QUEDARSE CON EL DUE O DE LA PISCINA PELIGRO PELIGRO DE ATASCAMIENTO MANT NGASE ALEJAD...

Страница 52: ...omba puede producir altos niveles de succi n del lado de la succi n del sistema de conexiones Estos niveles elevados de succi n pueden representar un riesgo si una persona se encuentra muy cerca de la...

Страница 53: ...corriente Modo de bloqueo de teclado Acepta entradas digitales de bajo voltaje provenientes de controles externos Bomba SuperMax VS Descripci n general del controlador La bomba de velocidad variable S...

Страница 54: ...D est apagado significa que la bomba no puede funcionar con ning n tipo de entrada 4 Indicadores LED de modo de visualizaci n Un indicador LED indica la informaci n que se visualiza en la pantalla en...

Страница 55: ...spa como sea posible Para reducir la p rdida de la fricci n y mejorar la eficiencia usar tuber as de succi n y retorno cortas y directas 2 Instalar a un m nimo de 5 pies 1 52 metros de la pared interi...

Страница 56: ...as conexiones del motor Espere siempre cinco 5 minutos despu s de desconectar la energ a de la bomba antes de abrir o hacer el mantenimiento del accionador 2 Elija un tama o de cable para la bomba de...

Страница 57: ...cidades se deben cablear como se muestra en la Figura 4 Cuando hay una se al de bajo voltaje en la l nea de entrada digital de velocidad la bomba funcionar a la velocidad programada para la velocidad...

Страница 58: ...D 2 ANARANJADO ENTRADA DIGITAL DE VELOCIDAD 3 MARR N ENTRADA DIGITAL DE VELOCIDAD 4 NEGRO CONEX A TIERRA Figura 5 Diagrama de cableado para la fuente de alimentaci n de bajo voltaje Para activar el mo...

Страница 59: ...adear Nota Cuando vuelva la electricidad a la bomba despu s de un corte prolongado m s de 24 horas el reloj se configurar autom ticamente con la hora de inicio en velocidad 1 parpadear y funcionar La...

Страница 60: ...l presionar el bot n 1 continuar pasando de uno de estos par metros al otro pero los cambios se guardan inmediatamente luego de ajustados 9 Presione el bot n 2 El indicador LED que se encuentra sobre...

Страница 61: ...0 segundos posteriores Si el modo Quick Clean Limpieza r pida se encuentra en ejecuci n y desea detener la limpieza r pida antes de completar la duraci n puede mantener presionado el bot n Quick Clean...

Страница 62: ...la temperatura del agua la presi n atmosf rica y el nivel de agua de su piscina Se deben considerar todos estos elementos al configurar la velocidad de cebado aunque en muchos casos la bomba no preci...

Страница 63: ...ado el bot n Quick Clean Limpieza r pida durante m s de tres 3 segundos cancela el modo de limpieza r pida Nota Durante el modo de limpieza r pida la bomba no inicia la secuencia de cebado Nota Se rec...

Страница 64: ...s las pantallas para ver la configuraci n Tambi n registre la velocidad de cebado 3 Mantenga presionados los botones 1 2 3 y Quick Clean Limpieza r pida durante 3 segundos 4 En la pantalla se visualiz...

Страница 65: ...es responsable de determinar cu ndo es probable que se produzcan condiciones de congelamiento Si se esperan temperaturas muy bajas siga los pasos a continuaci n para reducir el riesgo de da os por con...

Страница 66: ...bra con mucho cuidado Aseg rese de no rayar o arruinar las superficies pulidas del sello del eje el sello tendr fugas si las superficies est n da adas Las superficies pulidas y plegadas del sello pued...

Страница 67: ...l asiento fijo Presione el sello dentro de la placa de sello con sus pulgares y limpie la cer mica con un pa o limpio 4 Atornille el impulsor al eje del motor aj stelo en el sentido de las manecillas...

Страница 68: ...ire o fugas en la l nea de succi n Impulsor obstruido Colador de la bomba obstruido Verifique la tuber a de succi n y los casquillos de v lvulas de todas las v lvulas de entrada de succi n Asegure la...

Страница 69: ...ores internos Estos errores pueden producirse seg n las condiciones de funcionamiento y la UL 60730 necesaria para el software de seguridad de autodiagn stico Si no se resuelven despu s de varios inte...

Страница 70: ...EL DIFUSOR fabricado despu s 6 17 19 10 351094 BASE 11 357161 TAP N DE DRENAJE 12 192115 JUNTA T RICA TAP N DE DRENAJE 13 351089 VOLUTA 14 357255 JUNTA T RICA TAPA 15 355667 CANASTA 16 350091 TAPA N d...

Страница 71: ...Carga continua m xima 2 2 THP 115 voltios WEF 7 3 THP 2 2 230 voltios WEF 6 6 THP 2 2 Rango de velocidad 300 3450 RPM Calificaci n ambiental NEMA Tipo 3 Condiciones ambientales Almacenamiento 40 C a 8...

Страница 72: ...y marcas de terceros que puedan haber sido utilizados en este documento no indican una asociaci n o respaldo entre los propietarios de estos nombres comerciales y marcas y Pentair Water Pool and Spa I...

Отзывы: