19
SUPERMAX
®
VS Variable Speed Pump Installation and User’s Guide
10.62
269.7
12.52
318
9.33
237
7.74
196.6
6.32
160.5
8.98
228
14.24
361.6
10.07
255.7
8.71
221.3
7.71
195.9
Pump Specifications
Pump Dimensions
Overall Ratings
Input Voltage
115-230 Vrms nominal
Input Current
13.2/12.0-11.5 A
Input Frequency
Single phase, 50 or 60 Hz
Control Terminals
18-30V AC (24V AC+/- 20%) or
9-30V DC (12/24V DC +/- 20%)
Maximum Continuous Load
2.2 THP
115-volt:
WEF 7.3 THP 2.2
230-volt:
WEF 6.6 THP 2.2
Speed Range
300 - 3450 RPM
Environmental Rating
NEMA Type 3
Ambient Conditions
Storage
-40ºC to +85ºC (-40ºF to +185°)
Operating
0ºC to +50ºC (+32°F to +122°F)
Humidity
Relative 0 to 95 % non-condensing
Pump Performance Curves
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
50
60
70
80
90
100
110
120
To
tal Dy
namic
Head in Ft of H2
O
Volumetric Flow Rate in GPM
Quick Clean / 3450 RPM
(230V Only)
Quick Clean / 3450 RPM
(115V Only)
Speed 1 / 3000 RPM
(115V / 230V)
Speed 3 / 2200 RPM
(115V / 230V)
Speed 2 / 1400 RPM
(115V / 230V)