2.10 FINISHING AND TESTING
For the final step, follow the steps below finishing and testing the sensors and feeders.
1.
Route the sensor wires through the small strain relieves into the SR6000S and
install them into the appropriate connectors in the control board.
2.
Wire the sensors to the SR6000S.
The polarity (+ and -) of the pH and ORP sensors
must be observed. The ORP sensor (+) is color-coded red and the pH sensor (+) is
color-coded blue, the green leads are (-) polarity. Do not cut the sensor wires.
3.
After the wiring is complete, close the panel and tighten the screws. Leave excess
wire outside of controller box. Do not stuff excess wire inside the controller.
4.
Turn the power ON to the SR6000S.
5.
Calibrate the probes with the system water at pH and ORP set points, then recalibrate
as the probes acclimate to the pool.
6.
Visit the SR6000S over next few days to check the calibration and tune if necessary.
NOTE: try to check the calibrations at the same time of day as when they were
previously performed. Don’t re adjust calibration unless pH is more than +/- 0.5 off or
ORP is more than +/- 5 off.