1
S
TA
-R
ITE
I
NSTALLATION
&
O
PERATION
G
UIDE
STA-RITE
®
SR6000S
POOL / SPA
CONTROLLER
STA-RITE INDUSTRIES
293 Wright Street
Delavan, WI 53115
Ph (800) 752-0183
INSTALLATION &
OPERATION GUIDE
Software Version
SR6000S Release
A1
Feb. 28, 2003
Страница 1: ...INSTALLATION OPERATION GUIDE STA RITE SR6000S POOL SPA CONTROLLER STA RITE INDUSTRIES 293 Wright Street Delavan WI 53115 Ph 800 752 0183 INSTALLATION OPERATION GUIDE Software Version SR6000S Release A1 Feb 28 2003 ...
Страница 2: ...LECTRODE CARE 11 2 10 FINISHING AND TESTING 12 3 0 OPERATION OF SR6000S 13 3 1 INTRODUCTION 13 3 2 LED SUMMARY TABLE 13 3 3 INITIALIZING THE SR6000S 14 3 4 READING DISPLAY 14 3 5 MANUAL FEED 15 3 6 PH AND ORP MENU ITEMS 15 3 7 PH ORP SET POINTS 16 3 8 CYCLE TIME 16 3 9 ON TIME LIMIT 17 3 10 CALIBRATION 18 3 11 CALIBRATING PH 18 3 12 CALIBRATING ORP 18 3 13 OVERFEED TIME LIMIT 19 4 0 ADVANCED MENU ...
Страница 3: ...a ground fault circuit interrupter GFCI Contact a qualified electrician if verification on the receptacle is not protected by GFCI a Do not bury cord Route cord to eliminate abuse from heater exhaust lawn mowers hedge trimmers and other equipment a Be careful not to damage any of the cord insulation Should the cord be damaged return it to your dealer for a replacement Continued use could result in...
Страница 4: ...ning electrical storms floods etc In addition attempting to service or modify the Product will render this Warranty Void Defective parts should be returned immediately to the local Sta Rite dealer any parts returned to the factory require a return of material authorization code WARRANTY CARD MUST BE COMPLETED AND RETURNED AT ONCE 1 0 SR6000S OVERVIEW Sta Rite the technological leader in swimming p...
Страница 5: ...motely and on sight ALARMS If the pH or ORP is more than 5 away from set point for 10 minutes or more the SR6000S will light the LED alarm LEDS BUILT IN CHEMICAL FEEDERS Two 24 volt chemical feed pumps are built onto the sides of the SR6000S for ease of use and installation SENSORS The SR6000S directly measures pH and ORP Each sensor has its own isolated circuitry for direct measurement without th...
Страница 6: ... to follow when installing the electrical and plumbing portions Chapter three 3 the Programming and Operation describes all the available functions of the controller from navigating to initializing the SR6000S If there are any questions after reading this manual please contact your local Sta Rite dealer or Sta Rite directly 1 3 IMPORTANCE OF WATER MAINTENANCE The SR6000S will effectively maintain ...
Страница 7: ...t least ten 10 feet from open water Close enough for the supplied power cord to reach the supply voltage The controller will not operate properly without a solid earth ground connection WARNING Proper and safe operation requires an earth ground connection Supply power must be routed to the SR6000S in accordance with the applicable codes in the area the supplied cord is not code in some areas WARNI...
Страница 8: ... specific installation which are listed as follows Identify the new and existing equipment to be connected When controlling chemicals locate a location for the AK1200 flow cell if purchased Determine the water tap points for the bypass inlet and outlet Install the bypass Install the pH and ORP sensors Test the plumbing for leaks WARNING BE SURE TO HAVE A LICENSED PLUMBER PERFORM ALL PLUMBING THIS ...
Страница 9: ...ING WHEN USING ANYTHING OTHER THAN STA RITE SWITCH DEVICES THE FLOW SWITCH MUST NOT SUPPLY ANY VOLTAGE TO ANY SWITCH INPUTS OR DAMAGE MAY OCCUR WHICH IS NOT COVERED BY THE WARRANTY 2 5 ELECTRICAL SPECIFICATIONS The following electrical specifications in the table below must not be exceeded ITEM DESCRIPTION LIMIT Input Voltage Maximum Input AC Voltage 250 VAC Input Current Maximum Current 5 Amps AC...
Страница 10: ...the equipment using the SR6000S manual feed WARNING Be sure to have a licensed electrician perform all electrical wiring this is important as they will be familiar with all the codes in the local area 2 7 SENSORS Each sensor has its own unique circuitry that is connected directly to the micro controller for direct measurement The pH and ORP sensors are isolated from each other and from the input p...
Страница 11: ...he cables identify ORP probes 2 9 ELECTRODE CARE Contamination of the sensing elements often results in slow response and inaccurate readings Clean the elements by the following procedures Wash electrode tip in a liquid detergent and water Carefully use a soft bristled toothbrush to wash the electrode tip and white sensing ring Rinse after cleaning Swirl tip in a 5 parts water 1 part muriatic acid...
Страница 12: ...r coded blue the green leads are polarity Do not cut the sensor wires 3 After the wiring is complete close the panel and tighten the screws Leave excess wire outside of controller box Do not stuff excess wire inside the controller 4 Turn the power ON to the SR6000S 5 Calibrate the probes with the system water at pH and ORP set points then recalibrate as the probes acclimate to the pool 6 Visit the...
Страница 13: ...ilable menus of the SR6000S from navigating and initializing the system Please read carefully and take notice of all WARNINGS and Notices to ensure safe operations If there are any questions after reading through this guide please call your local STA RITE dealer or call STA RITE directly 3 2 LED SUMMARY TABLE The SR6000S has five LED to indicate various conditions these conditions are explained in...
Страница 14: ...rief check of its internal system and check its memory for operation It will also display the date code for the version of software that the system is currently using As listed below the software version is dated 02 17 03 or Feb 17 2003 Note When contacting Sta Rite for technical support be sure to have this information available to give to them 3 4 READING DISPLAY During normal operation the read...
Страница 15: ...ORP menu is active both the ORP FEED LED and ORP ALARM LED will be lit all other LEDs will be off Both pH and OPR menus have the same 5 choices outlined below 1 Set Point value StP Sets the value that you would like the controller to maintain the pH or ORP levels 2 Cycle time CyC The time that you want a feed pump on off cycle in seconds 3 On Limit OnL Sets the maximum time that you want the contr...
Страница 16: ...to set the ORP set point value Note Changes in values are immediate and do not need to be saved as a separate step pH Set Point Display 3 8 CYCLE TIME Pressing either the pH or ORP Menu buttons twice lets you set the maximum time that you want the controller to complete a full on off cycle Pressing the button will increase the time value and pressing the will decrease the time value that you want ...
Страница 17: ... LIMIT Pressing either the pH or ORP Menu buttons three times lets you set the maximum time that you want the controller to be on during the cycle time This allows you have a minimum off time before the beginning of the next cycle For example if you have a Cycle Time of 12 seconds and an On Time Limit of 5 seconds the minimum off time would be 12 5 7 seconds Pressing the button will increase the t...
Страница 18: ... the value and press the button to decrease the value 3 12 CALIBRATING ORP WARNING The pH MUST be at set point the pH calibration explained above MUST be complete and the pH feed pump should be operating normally and maintaining a constant pH before calibrating ORP To calibrate the ORP sensor Hand feed Cl into the pool until the PPM level is at the desired control point Make sure your ORP set poin...
Страница 19: ...time 4 0 ADVANCED MENU Under normal operating conditions you should not need to go into the advanced menus If you do need to access the advanced menus press both the and buttons simultaneously When in the advanced menu all five of the LED s will turn ON While in the advanced menu you can scroll through the readings by pressing the ORP MENU button The menu items that can be accessed and changed are...
Страница 20: ... value has changed Clear pH Calibration Display 4 2 CLEAR ORP This menu allows you to clear the ORP calibration back to factory default Press the ORP MENU button once In order to reset the ORP calibration value press the SELECT button and you will see the display that is showing the PH change to yES so that you will know that the value has changed Clear pH Reading Clear ORP Calibration Display pH ...
Страница 21: ... display Acid Select Display 4 4 SET PASSWORD The forth item in the Advance Menu is Set Password The password can be any number between 0 999 To enter the number you want press the button to increase the number and press the button to decrease the password number The moment any number other than zero is entered password protection will be enabled When password protection is enabled you will have t...
Страница 22: ...likely solution For other problems please contact STA RITE s technical support Part Problem Solution 1 Solution 2 Alarm LED Alarm LED ON Increase ON time if Check for empty Chemical Below set point Tanks Feed Pump tube is old Flow Flow Cell magnet will not go up Clean Filter Backwash main filter ORP pH Probe Readings Bouncing Clean Probe Check water flow Flow Switch Not Working Check for magnet Ch...
Страница 23: ...ange out the feed tube in the pump Contact STA RITE for parts WARNING Used extreme caution while working on chemical feed lines Wear protective equipment to protect the eyes face and hands from chemical spray Important If any problems remain after reading the guides and troubleshooting procedures please contact STA RITE directly at 1 800 752 0183 Before calling please have the following items avai...
Страница 24: ...and snap cover off of the pump housing 5 With touching the spring remover pump rotor assembly 6 Remove tube from pump housing by working loose the tube stems from the housing 7 Install new tube making sure tube stems are locked into housing tube stem collars DO NOT put any twists in the tube during installation 8 With high grade silicone based grease lubricate the housing hole and the cover hole f...
Страница 25: ...0 pH 7 2 7 4 7 6 7 8 Total Alkalinity PPM 60 80 100 180 0 TDS PPM 300 1000 2000 3000 0 Calcium Hardness PPM 150 300 400 500 1000 Cyamuric Acid PPM 10 30 50 150 For Liquid chlorine Cal Hypo and Lithium Hypo for Gas Chlorine Dichlor Trichlor and Bromine compounds 100 200 is ideal Except where limited by Health Departments requirements often to 100 PPM Table for Spa s Minimum Ideal Maximum Free Chlor...