background image

14

Motor No.

Impeller

Model No.

HP

(Key No. 1)

(Key No. 10)

230 Volt/1 Phase
PE6H-139L

3

AE100HLL

C105-137PKBA

PE6H-139LC

3

AE100HLL

C105-137PKBA

230/460 Volt/3 Phase
PE6H3-139

3

AP100HL

C105-137PKBA

230 Volt/1 Phase
PE62H-139

3

AE100HL2

C105-137PKBA

Parts are common to all models listed except as noted;
Key Nos. 1, Motor; and 10, Impeller are listed below.

Key

Part 

Part 

No.

Description

Qty.

No.

1

Motor

1

Chart at Right

2

Screw, #10-32x1/2”  

1

U30-692SS

3

Bonding Lug

1

U17-568

4

Water Slinger

1

C69-2

5

Seal Plate

1

C203-137P1

6

O-Ring

1

U9-228A

7

Insert

1

J3-2

8

Shaft Seal

1

U109-93SS

9

Clamp

1

C19-37A

Clamp Knob

1

WC36-22

10 Impeller

1

Chart at Right

Impeller Screw

1

C30-12

11 Diffuser

1

C1-259P

12 Screw, #8-32x7/8”

5

U30-542SS

13 Washer, #8 Lock 

5

U43-21SS

14 Diffuser O-Ring

1

U9-226

15 Tank Body

1

C176-47P1

16 1/4” NPT Drain Plug 

1

U178-920P

17 Base w/Motor Pad

1

C104-41P

18 Motor Pad

1

C35-11

19 Washer, Flat

2

U43-42SS

20 Screw, 3/8-16x1-3/4” Soc. Hd.  

2

U30-778SS

21 Screw, 3/8-16x1” Soc. Hd.

2

U30-99SS

Reducer 2”x1-1/2”

1

C78-7P

Decal “Suitable for outdoor use...”

U27-635

Decal “IMPORTANT-Do not use pipe 
dope...”

WC27-27

Voltage Sticker - 230 Volts

U27-68

Tag, “CAUTION”

61002-0002

Tag, “CAUTION, WARNING
(bonding)”

C63-12

Nameplate

U33-121

• Not illustrated.

PE5 and PE52 model include 5” trap, Pkg. 115.
PE6 models include 6” trap, Pkg. 161.
PEX models do not include trap.
For trap parts, see Page 15.
For Parts-Pak parts, See Page 15.

1

2

3

4

19

20

8

5

6

9

10

11

14

15

16

12

13

17

18

7

21

1831 0695

REPAIR PARTS LIST

PE SERIES

MAX-E-GLAS POOL PUMP

3 HP Models

Содержание MAX-E-GLAS PE Series

Страница 1: ...2G 122 3 PE6H 139L PE62H 139 3 PE6H 139LC PE6H3 139 Sta Rite Pool Spa Group 600 S Jefferson Street Waterford WI 53185 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728...

Страница 2: ...he Sta Rite PE Series Self priming Centrifugal pump Is designed for use with swimming pools or as a centrifugal pump Is an excellent performer durable reliable Table of Contents Safety Instructions 3...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...CE Use Teflon tape or Plasto Joint Stik1 for making all threaded connections to the pump Do not use pipe dope pipe dope will cause stress cracking in the pump NOTICE Pump suction and discharge connect...

Страница 5: ...ical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to Motor Dist in Ft M Motor Branch Fuse Max Load Voltage 0 100...

Страница 6: ...mm solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or con...

Страница 7: ...Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to tighten cover NOTICE Tighten trap cover by hand only no wrenches Use a wrench only if necessary to remove...

Страница 8: ...tem Propylene glycol is non toxic and will not damage plastic system components other anti freezes are highly toxic and may also damage plastic components in the system Drain all water from pump and p...

Страница 9: ...e 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulled away from pump body 5 Remove five screws and washers holding di...

Страница 10: ...unterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 5 16 1 cent kg torque 9 Assemble motor and seal plate to volute be sure clamp is properly seated NOTICE Clamp knob can...

Страница 11: ...er 7 Make sure impeller is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8...

Страница 12: ...Clamp Knob 1 WC36 22 10 Impeller 1 Chart at Right 11 Diffuser 1 C1 200PA 12 Screw 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drai...

Страница 13: ...w 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drain Plug 1 U178 920P 17 Base w Motor Pad 1 C104 42P 18 Motor Pad 1 C35 11 19 Washer...

Страница 14: ...C30 12 11 Diffuser 1 C1 259P 12 Screw 8 32x7 8 5 U30 542SS 13 Washer 8 Lock 5 U43 21SS 14 Diffuser O Ring 1 U9 226 15 Tank Body 1 C176 47P1 16 1 4 NPT Drain Plug 1 U178 920P 17 Base w Motor Pad 1 C104...

Страница 15: ...Capscrew 5 16 18x1 1 4 U30 64SS 4 U30 64SS 4 8 Washer Lock 5 16 U43 11SS 4 U43 11SS 4 9 Washer Flat 5 16 U43 41SS 4 U43 41SS 4 Quantity one unless otherwise indicated Overhaul Kits H P Parts Pak Numbe...

Страница 16: ...ence misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...