ELECTRICAL

Hazardous Voltage. Can cause severe or

fatal electric shock.

Pump is supplied with a grounding con-

ductor and ground ding-type attachment plug. To reduce risk
of electric shock, be certain that it is connected only to a
properly grounded, grounding type receptacle. Ground termi-
nal on pump cord plug is provided for your protection. DO
NOT REMOVE!

OPERATION / MAINTENANCE

Risk of electric shock. Before attempting to

check why unit has stopped operating, disconnect power
from unit. Do not handle pump with wet hands or when
standing on wet or damp surfaces, or in water.

Risk of flooding.

If a flexible discharge hose

is used, pump may move when motor starts. If the switch hits
the side of the sump, the switch may stick and prevent the
pump from starting. Make sure the pump is secured so it
cannot move around in sump.

Risk of sudden starts. The pump motor is

equipped with automatic resetting thermal protector and
may restart unexpectedly.

1.

If protector trips, motor may be overloading. Check for
the following problems:
A. Not enough back pressure in discharge pipe.
B. Voltage too high or too low.
C. Wires to motor too small.
D. Motor incorrectly connected to power supply wires.
E. Defective motor.

2.

Shaft seal depends on water for lubrication and cooling.
Do not operate pump unless it is submerged in water as
seal may be damaged if allowed to run dry.

3.

Motor is equipped with automatic reset thermal protector.
If temperature in motor should rise unduly, switch will cut
off all power before damage can be done to motor. When
motor has cooled sufficiently, switch will reset automati-
cally and restart motor. If protector trips repeatedly,
unplug the pump and remove it; check for cause of diffi-
culty. Low voltage, long extension cords, clogged
impeller, very low head or lift, etc., could cause cycling.

4.

Pump will not remove all water. If manually operated
pump is operating and suddenly no water comes out dis-
charge hose, shut off unit immediately. Water level is
probably very low and unit has broken prime.

NOTICE:

For continuous operation, water depth must be

at least 5" (127mm) to prevent motor overheating.

AUTOMATIC FLOAT SWITCH -
INSTALLATION

1.

Install pump following installation and operating instructions.

2.

Automatic float switch is sealed and factory adjusted for
most home sumps. See Page 1 for switch settings.

3.

Be sure that horizontal float switch clearance is 8”. For
best performance of pumps with tethered switches, sump

diameter and sump depth should be at least 14”. For
best performance of pumps with vertical switches, sump
diameter must be at least 10”.

4.

Plug piggyback switch cord into 115V AC outlet. Then,
plug pump into piggyback switch cord.

NOTICE:

Call Customer Service for minimum recom-

mended turn-off level above pump base.
Do not allow cord to interfere with float control motion or to
drape over pump motor. With electrician's tape or cable
ties secure cord to discharge pipe for cord protection.

FLOAT SWITCH - 
OPERATIONAL CHECK 

1.

Fill the sump with correct amount of water to check oper-
ation an tightness of connections. During the first auto-
matic cycle, it may take 30 seconds or more before pump
is primed and pumping. Pump will start as indicated in
the “Motor, Switch and Cord” Specifications Table, Page
1.

2.

Check turn-off position. Pump will stop approximately as
indicated in the “Motor, Switch and Cord” Specifications
Table, Page 1.

3.

If pump does not operate check electrical service.

NOTICE:

Float switch tether length is set at factory. It is

3-1/2” (89mm) for D125, D133, and D150 Series and 3”
(76mm) for D175 Series pumps. Do not change tether
length of float switch. Float must swing through its com-
plete arc without interference.

To Clean Impeller
D125, D133 and D150 Series Models

Follow steps 1, 2, 3, and 4, shown below. To reassemble
pump, reverse the sequence.

A. Complete repairs and replace pump in pit before plug-

ging it in again.

B. Do not raise, lower, or carry pump by the power cord.

use the tee-handle provided.

3

320 0395-1

320 0395 2

320 0395 3

342 0395

4

Float Switch Tether Length

3

2

1

Varies - See

“NOTICE”

Below

Содержание D125 Series

Страница 1: ...elease all pressure within system before servicing any component 4 Drain all water from system before servicing 5 Secure discharge line before starting pump An unse cured discharge line will whip poss...

Страница 2: ...c pipe A For D125 D133 and D150 Series Wrap thread with Teflon tapeTM Screw pipe into pump hand tight 1 1 1 2 turns Thread outlet pipe into pump body carefully to avoid stripping or crossing threads B...

Страница 3: ...se shut off unit immediately Water level is probably very low and unit has broken prime NOTICE For continuous operation water depth must be at least 5 127mm to prevent motor overheating AUTOMATIC FLOA...

Страница 4: ...1 PS1 21P PS1 21P PS1 21P 8 Impeller 1 See Chart Below See Chart Below See Chart Below 9 Volute Lower 1 FP0005781 FP0005781 FP0005781 10 Screw 8 16x1 2 Lg Pan Head 7 U30 934ZP U30 934ZP U30 934ZP Scr...

Страница 5: ...Switch Cord Clamp 1 CC0030 13 CC0030 13 6 Nut Acorn SS 1 U36 203SS U36 203SS 7 Screw Panhead 1 U30 971SS U30 971SS 8 Automatic Float Switch Assembly 1 PS17 109 PS17 111 9 Upper Pump Housing 1 12920 1...

Страница 6: ...Pro SourceTM Steel Pressure Tanks 5 years from date of original installation Pro SourceTM Epoxy Lined Tanks 3 years from date of original installation Sump Sewage Effluent Products 12 months from date...

Страница 7: ...dentro del sistema antes de realizar tra bajos de reparaci n o mantenimiento en cualquiera de los com ponentes 4 Drene toda el agua del sistema antes de realizar trabajos de reparaci n o mantenimient...

Страница 8: ...on cinta de Tefl nTM Atornille el tubo en la bomba a mano dando entre 1 y 1 1 2 vueltas Enrosque el tubo de sali da en el cuerpo de la bomba con cuidado para evitar que las roscas se deformen o se cru...

Страница 9: ...undidad del agua debe ser por lo menos de 5 127 mm para evitar que el motor se recaliente CONMUTADOR AUTOM TICO DE FLOTACI N INSTALACI N 1 Instale la bomba siguiendo las instrucciones de instalaci n y...

Страница 10: ...illo cabeza hexagonal 8 32x7 8 4 U30 951PS U30 951PS U30 951PS 6 Motor 1 7 Voluta superior 1 PS1 21P PS1 21P PS1 21P 8 Impulsor 1 Ver tabla a continuaci n Ver tabla a continuaci n Ver tabla a continua...

Страница 11: ...l conmutador 1 CC0030 13 CC0030 13 6 Tuerca ciega SS 1 U36 203SS U36 203SS 7 Tornillo cabeza de cono achatado 1 U30 971SS U30 971SS 8 Ensamblaje del conmutador autom tico de flotaci n 1 PS17 109 PS17...

Страница 12: ...8 meses desde la fecha de fabricaci n Tanques de compuesto Pro SourceMC 5 a os desde la fecha de la instalaci n inicial Tanques a presi n de acero Pro SourceMC 5 a os desde la fecha de la instalaci n...

Отзывы: