ST7735R
V0.2
97
2009-08-05
10.1.14 INVOFF (20h): Display Inversion Off
20H
IVNOFF (Normal Display Mode Off)
Inst / Para
D/CX
WRX
RDX
D17-8
D7
D6
D5
D4
D3
D2
D1
D0
HEX
INVOFF
0
↑
1
-
0
0
1
0
0
0
0
0
(20h)
Parameter
No Parameter
-
Description
-This command is used to recover from display inversion mode.
“-“ Don’t care
Default
Status
Default Value
Power On Sequence
Display Inversion off
S/W Reset
Display Inversion off
H/W Reset
Display Inversion off
Flow Chart
INVOFF (20h)
Command
Parameter
Display
Action
Mode
Legend
Sequential
transter
Display
Inversion On
Mode
Display
Inversion OFF
Mode
Top-Left
(0,0)
(Example)
Memory
Display