L6482
Programming manual
Doc ID 023768 Rev 1
49/73
Any attempt to write to the register when the motor is running causes the command to be
ignored and the NOTPERF_CMD to rise (see
).
9.1.13 TOFF_MIN
This parameter is used by the current control system when current mode operation is
selected.
The TOFF_MIN register contains the minimum off-time value used by the current control
system (see
for details).
The available range for both parameters is from 0.5 µs to 64 µs.
Any attempt to write to the register when the motor is running causes the command to be
ignored and NOTPERF_CMD to rise (see
).
Table 18.
Minimum on-time
TON MIN [6..0]
Time
0 0 0 0 0 0 0
0.5
µs
0 0 0 0 0 0 1
1
µs
…
…
…
…
…
…
…
…
1 1 1 1 1 1 0
63.5
µs
1 1 1 1 1 1 1
64
µs
Table 19.
Minimum off-time
TOFF MIN [6..0]
Time
0 0 0 0 0 0 0
0.5
µs
0 0 0 0 0 0 1
1
µs
…
…
…
…
…
…
…
…
1 1 1 1 1 1 0
63.5
µs
1 1 1 1 1 1 1
64
µs