L6482
Electrical characteristics
Doc ID 023768 Rev 1
15/73
t
cpwu
Charge pump power-on and wake-up time
Power bridges
disabled,
C
p
= 10 nF, C
boot
= 220
nF, V
CC
=15 V
1
ms
Internal voltage regulators
V
CCOUT
Internal V
CC
voltage regulator output voltage
Low (default), I
CC
= 10
mA
7.3
7.5
V
High, I
CC
= 10 mA
4
15
V
CCREG, drop
V
SREG to
V
CC
dropout voltage
I
CC
= 50 mA
3
V
P
CC
Internal V
CC
voltage regulator power
dissipation
2.5
W
V
REGOUT
Internal V
REG
voltage regulator output
voltage
I
REG
= 10 mA
3.13
5
3.3
V
V
SREG, drop
V
CCREG
to
V
REG
dropout voltage
I
REG
= 50 mA
3
V
I
REGOUT
Internal V
REG
voltage regulator output
current
VREG pin shorted to
ground
125
mA
I
REGOUT,STB
Y
Internal V
REG
voltage regulator output
standby current
VREG pin shorted to
ground
55
mA
P
REG
Internal V
REG
voltage regulator power
dissipation
0.5
W
Integrated analog-to-digital converter
N
ADC
Analog-to-digital converter resolution
5
bit
V
ADC,ref
Analog-to-digital converter reference voltage
3.3
V
f
S
Analog-to-digital converter sampling
frequency
(2)
f
OSC/512
kHz
V
ADC,UVLO
ADCIN UVLO threshold
1.05
1.16
1.35
V
1.
Guaranteed in the temperature range -25 to 125
°
C
.
2.
The value accuracy is dependent on oscillator frequency accuracy (
).
3.
FLAG and BUSY open drain outputs included.
4.
See
Table 5.
Electrical characteristics (continued)
Symbol
Parameter
Test condition
Min.
Typ.
Max. Unit