TROUBLESHOOTING & FRQUENTLY ASKED QUESTIONS

 

 
 
Your Stove is very trouble free in operation when properly maintained and quality fuel is 
used. When the Stove fails to operate properly, troubleshoot your stove by following the 
suggestions listed below.  
 

Please read the following guide for answers to frequently asked questions 

 

1.

 

When  first  starting  the  Stove,  the  auger  tube  is  empty,  which  will  delay  feeding  fuel  to 
the burn pot. This will in some cases prevent the Stove from starting. 

 

 
Solution:

  

Prime the burn pot using the Auger Feed button if the auger tube is empty. 

 

2.

 

My Stove keeps overloading the burnpot.

 First check the moisture content of your fuel. 

It  should  be  15%  or  less.  Also  make  sure  you  are  using  clean  fuel.  Otherwise  this  is 
mainly  caused  by  improper  combustion.  (See 

Damper 

Adjustment  section  of  the 

Operations Manual) Besides the damper adjustment there are several areas that can have 
an effect on the combustion process.  
 

Solution: 

Check  all  Gaskets,  Doors  and  Door  Latching  Systems  for  air  leaks.  Any 

leaks in these areas will negatively affect the burn process and cause the pot to overload. 

 

 

3. 

My Stove isn’t burning and the number 2 LED light is blinking.

 This diagnostic light 

indicates the vacuum switch no longer senses negative pressure in the firebox area of the 
Stove. What caused the Stove to go out?

 

 

a. 

The door of the unit was left open longer than 60 seconds. 

(See solution)

 

b. 

The ash pan door was left open for longer than 60 seconds. 

(See solution)

 

c. 

The combustion fan is not running. (Defective fan or control board) 

d. 

The vacuum switch is defective. 

e. 

The vacuum hose is disconnected 

f.

 

The vent system is plugged with fly-ash. 

 

Solution: 

If the fire is out

 

and the stove is off

 simply re-light the Stove, however 

if 

the fire is still burning in the burn pot

 make sure all doors are securely latched

 

and

 

hold 

down the On/Off

 

button (approximately 5 seconds) until Stove starts up again. This will 

re-start the Stove in the start-up program.

 

 

 

4. 

My Stove isn’t burning and the number 3 LED light is blinking.

 This diagnostic light 

indicates that the Proof of Fire Switch no longer senses a fire in the Stove. First check to 
see if there are pellets in the hopper. If there are pellets in the hopper, we need to figure 
why the Stove went out. 

 

Содержание DHC3000

Страница 1: ...4000 Series Board that we introduced about 3 years ago with some of our newer models Please take a look at the 2 control boards below If your Control Board looks like one of these or is even older and...

Страница 2: ...s control board offers more Feedrate adjustments and Draft Fan voltage adjustments This allows for more user friendly control over how the stove burns based on the quality of fuel Please take the time...

Страница 3: ...nd starts feeding pellets on the 1 setting Once the board senses P O F the Igniter shuts off and the stove has started successfully d If the board fails to sense P O F it will repeat the previous step...

Страница 4: ...up speed until the Proof of Fire Switch locks in c After 5 minutes the board checks for Proof of Fire and automatically starts feeding Fuel on the 1 setting If the board senses P O F then the stove ha...

Страница 5: ...ese areas will negatively affect the burn process and cause the pot to overload 3 My Stove isn t burning and the number 2 LED light is blinking This diagnostic light indicates the vacuum switch no lon...

Страница 6: ...light the Stove or tighten the setscrew on the auger shaft 5 My Stove isn t burning and the 4 LED light is blinking This means the high Limit has shut the Stove down The Convection Blower could be de...

Страница 7: ...creasing the feedrate LED s 1 2 The ON time is increased or decreased 25 seconds with each adjustment 9 Are there any adjustments that can be made through the control board to the Combustion Fan volta...

Страница 8: ...he LED s flash three times This program is for use with Pellets Cherry Pits This program does have Self Ignition and is used in units that have the Versa Grate System Igniter installed This program is...

Отзывы: