4
MULTI-FUEL STOVES -
If you replaced Control Board
80P52632B
or any similar
Digital Multi-Fuel Stove Control
Board
, please use the following instructions on how to
light your stove.
1. Make sure there is Fuel in the hopper.
2. Add one cup of
Pellets
to the burn pot (not more and not less). Do not try to start your stove
with corn or other small grains; Grain is difficult to start. Add a generous amount of starter
gel to the pellets.
3. This next item is optional, but it will give an immediate boost to the start up procedure.
Crumple up half of a newspaper page, light the gel and toss the paper in the burn pot.
4. Close the door and push the On/Off button on the control board.
5.
Set the controls to Heat Level #1
6.
Once the Proof of Fire switch locks in and the Power Light quits blinking, adjust the heat
level to the desired level.
The Start up Program works as follows:
a.
The Combustion Fan comes on at high speed and the control board checks to make
sure the Vacuum switch locks in.
b.
When the Control Board senses the Vacuum switch the Exhaust Fan drops to a lower start up
speed until the Proof of Fire Switch locks in.
c.
After 5 minutes the board checks for “Proof of Fire” and automatically starts feeding Fuel on
the #1 setting. If the board senses P.O.F. then the stove has started successfully.
d.
If the board fails to sense P.O.F. after 5 minutes it will repeat the last step and continue
feeding corn on the #1 setting for 5 more minutes.
e.
The board will check for P.O.F. again. If the board still fails to sense the Proof of Fire switch
the stove will go into “Safety shutdown”
If stove fails to start, repeat steps 2 through 6 listed above.
Shutting the Unit Off
1. Press the On/Off switch once; the lights will go off and the fire will go out in a few
minutes. The board essentially goes into “Safety shutdown”.
2.
As long as the temperature within the Ashby-MF remains above 110°F the both Fans
will continue to run. When the P.O.F. switch drops out, the room fan shuts of and the
Combustion fan will run for another 10 minutes and finally shut down completely.
3.
NEVER unplug the Multi-Fuel Stove to shut it off. Doing so may cause a significant
amount of smoke to enter the room.
Thermostat Slide Switch
– Only the Manual and T-Stat Position of the Slide Switch
work with the Multi-Fuel Stoves.