background image

MULTI-FUEL  STOVES  - 

If  you  replaced  Control  Board 

80P52632B

  or  any  similar 

Digital Multi-Fuel Stove Control 

Board

, please use the following instructions on how to 

light your stove.

  

 

1.   Make sure there is Fuel in the hopper. 

 

2.   Add one cup of 

Pellets

 to the burn pot (not more and not less). Do not try to start your stove 

with corn or other small grains; Grain is difficult to start. Add a generous amount of starter 
gel to the pellets.  

 

3.   This  next  item  is  optional,  but  it  will  give  an  immediate  boost  to  the  start  up  procedure. 

Crumple up half of a newspaper page, light the gel and toss the paper in the burn pot. 

 

4.   Close the door and push the On/Off button on the control board.

 

 

5.

  Set the controls to Heat Level #1 

 

6. 

Once the Proof of Fire switch locks in and the Power Light quits blinking, adjust the heat 
level to the desired level. 

 

The Start up Program works as follows: 

 

a.

 

The Combustion Fan comes on at high speed and the control board checks to make 
sure the Vacuum switch locks in.  

 

b.

 

When the Control Board senses the Vacuum switch the Exhaust Fan drops to a lower start up 
speed until the Proof of Fire Switch locks in. 

 

c.

 

After 5 minutes the board checks for “Proof of Fire” and automatically starts feeding Fuel on 
the #1 setting. If the board senses P.O.F. then the stove has started successfully. 

 

d.

 

If  the  board  fails  to  sense  P.O.F.  after  5  minutes  it  will  repeat  the  last  step  and  continue 
feeding corn on the #1 setting for 5 more minutes. 

 

e.

 

The board will check for P.O.F. again. If the board still fails to sense the Proof of Fire switch 
the stove will go into “Safety shutdown” 

 

If stove fails to start, repeat steps 2 through 6 listed above. 

 

Shutting the Unit Off 

 

1.  Press the On/Off switch once; the lights will go off and the fire will go out in a few 

minutes. The board essentially goes into “Safety shutdown”. 

 

2.

 

As long as the temperature within the Ashby-MF remains above 110°F the both Fans 
will continue to run. When the P.O.F. switch drops out, the room fan shuts of and the 
Combustion fan will run for another 10 minutes and finally shut down completely. 

 

3.

 

NEVER unplug the Multi-Fuel Stove to shut it off. Doing so may cause a significant 
amount of smoke to enter the room. 

 

Thermostat Slide Switch

 – Only the Manual and T-Stat Position of the Slide Switch 

work with the Multi-Fuel Stoves. 

SmartStat is incompatible with the Multi-Fuel Stoves.

  

 

Содержание DHC3000

Страница 1: ...4000 Series Board that we introduced about 3 years ago with some of our newer models Please take a look at the 2 control boards below If your Control Board looks like one of these or is even older and...

Страница 2: ...s control board offers more Feedrate adjustments and Draft Fan voltage adjustments This allows for more user friendly control over how the stove burns based on the quality of fuel Please take the time...

Страница 3: ...nd starts feeding pellets on the 1 setting Once the board senses P O F the Igniter shuts off and the stove has started successfully d If the board fails to sense P O F it will repeat the previous step...

Страница 4: ...up speed until the Proof of Fire Switch locks in c After 5 minutes the board checks for Proof of Fire and automatically starts feeding Fuel on the 1 setting If the board senses P O F then the stove ha...

Страница 5: ...ese areas will negatively affect the burn process and cause the pot to overload 3 My Stove isn t burning and the number 2 LED light is blinking This diagnostic light indicates the vacuum switch no lon...

Страница 6: ...light the Stove or tighten the setscrew on the auger shaft 5 My Stove isn t burning and the 4 LED light is blinking This means the high Limit has shut the Stove down The Convection Blower could be de...

Страница 7: ...creasing the feedrate LED s 1 2 The ON time is increased or decreased 25 seconds with each adjustment 9 Are there any adjustments that can be made through the control board to the Combustion Fan volta...

Страница 8: ...he LED s flash three times This program is for use with Pellets Cherry Pits This program does have Self Ignition and is used in units that have the Versa Grate System Igniter installed This program is...

Отзывы: