background image

 

 

 
 

Discontinued Models DHC3000 Control Boards

 

 

These  instructions  are  only  intended  for  customers  who  are  replacing  one  of  the 
discontinued control boards listed below 

 

The

 

Company  that  manufactures  the  St.  Croix  Control  Boards  has  reached  the  point  of 

discontinuing  another  older  model  Control  Board.  They  will  be  replaced  with  the 
DHC4000  Series  Board  that  we  introduced  about  3  years  ago  with  some  of  our  newer 
models. 

 

Please take a look at the 2 control boards below. If your Control Board looks like one of 
these or is  even older  and it doesn’t have the Thermostat Slide switch, then  your board 
has been discontinued.  

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

                             

80P52632B                                                          80P22348B 

           Auburn, Lancaster, Greenfield                      Afton Bay, Prescott, Hastings, York 

 

The new Control Board  is backwards compatible with the DHC3000  and plugs directly 
into  the  old  wiring  harness. 

The  Part  Number  for  your  replacement  board  is 

80P30523-R 

Содержание DHC3000

Страница 1: ...4000 Series Board that we introduced about 3 years ago with some of our newer models Please take a look at the 2 control boards below If your Control Board looks like one of these or is even older and...

Страница 2: ...s control board offers more Feedrate adjustments and Draft Fan voltage adjustments This allows for more user friendly control over how the stove burns based on the quality of fuel Please take the time...

Страница 3: ...nd starts feeding pellets on the 1 setting Once the board senses P O F the Igniter shuts off and the stove has started successfully d If the board fails to sense P O F it will repeat the previous step...

Страница 4: ...up speed until the Proof of Fire Switch locks in c After 5 minutes the board checks for Proof of Fire and automatically starts feeding Fuel on the 1 setting If the board senses P O F then the stove ha...

Страница 5: ...ese areas will negatively affect the burn process and cause the pot to overload 3 My Stove isn t burning and the number 2 LED light is blinking This diagnostic light indicates the vacuum switch no lon...

Страница 6: ...light the Stove or tighten the setscrew on the auger shaft 5 My Stove isn t burning and the 4 LED light is blinking This means the high Limit has shut the Stove down The Convection Blower could be de...

Страница 7: ...creasing the feedrate LED s 1 2 The ON time is increased or decreased 25 seconds with each adjustment 9 Are there any adjustments that can be made through the control board to the Combustion Fan volta...

Страница 8: ...he LED s flash three times This program is for use with Pellets Cherry Pits This program does have Self Ignition and is used in units that have the Versa Grate System Igniter installed This program is...