months. Run the Stove on the hottest setting once a day for 30 – 45 minutes to prevent
excessive build-up in the Stove.
- Have a clearly understood plan to handle a chimney fire. Contact the local fire department for
information if needed.
- Keep the doors closed and all seals in good condition while operating the Stove.
- INSPECT THE FLUE PIPES, JOINTS AND SEALS REGULARLY TO ENSURE THAT
SMOKE AND FLUE GASES ARE NOT DRAWN INTO, AND CIRCULATED BY THE
AIR-CIRCULATION SYSTEM.
- CLEANING OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY AND DRAFT
INDUCER IS ESPECIALLY IMPORTANT AT THE END OF THE HEATING SEASON TO
MINIMIZE CORROSION DURING THE SUMMER MONTHS CAUSED BY
ACCUMULATED ASH.
- The Stove will not operate during a power failure. Prolonged Power Outages will require the
use of a generator to operate the Stove.
Ash Pan Location
Figure 16
The above figure shows how to access the firebox ash pans, by removing the lower panel and
opening the firebox Ashpan door.
The Removable Lower Panel is held in place by Magnets. Simply hold each side of the Panel and
lift off of the insert. The 2 small Ash pans are located behind the Ashpan Door.