10
Stand alone operation
Master mode
Scan in the master fingerprint
Conditions:
• Device is initialized
• Red LED is alight (as‑delivered
status)
• Draw the master fingerprint over
the sensor. The green LED flashes for
appr. 3 seconds, after which the red
LED lights up.
• Draw the master fingerprint over
the sensor again. The green LED
flashes appr. 3 seconds, then the red
LED lights up.
• Draw the master fingerprint over
the sensor a third time. The green
LED flashes for appr. 3 seconds,
after which the green LED lights up
continuously.
The master fingerprint has now been
scanned in and is valid. It is now
possible to scan in user fingerprints.
If a finger has been drawn over
the sensor and not recognized, the
red LED flashes for 3 seconds, after
which the red LED lights up continu
‑
ously.
Repeat the scanning‑in process.
Scan in an user fingerprint
Conditions:
• Green LED is alight (operating
mode)
• Draw the master fingerprint once
over the sensor. The green LED
flashes for appr. 3 seconds, then the
red LED lights up.
• Draw the user fingerprint over the
sensor. The green LED flashes for
appr. 3 seconds, then the red LED
lights up.
• Draw the user fingerprint over the
sensor again. The green LED flashes
for appr. 3 seconds, then the red
LED lights up.
• Draw the user fingerprint a third
time over the sensor. The green LED
flashes for appr. 3 seconds, then
stays alight.
If a finger has been drawn over
the sensor and not recognized, the
red LED flashes for 3 seconds, after
which the red LED lights up continu
‑
ously.
Repeat the scanning‑in process.
Check:
• Draw the user fingerprint once
over the sensor.
The green LED flashes and the relay
picks up.
Changing the operating
mode
To change the operating mode, the
module can remain in the module
carrier.
In order to operate the FPM 611‑…
in accordance with special require‑
ments, before commissioning you
must have set the relevant operating
mode. The operating mode is set
from the back of the module:
Module removal
See product information sheet for
the Siedle Classic Installation instruc
‑
tions.
5
Setting the operating mode
• Open the flap on the back of the
module with the aid of a screw
‑
driver.
• Set the required operating mode
(0 to 9) at the rotary switch. Once
the required operating mode has
been set, close the flap and replace
the module.
Possible operating modes:
1
= Master mode
5
= Group administrator mode
9
= Administrator mode
0, 2..4 and 6..8
= Delete mode
Group administrator
mode
Scan in the group administrator
fingerprint
Conditions:
• Device is initialized
• Group administrator mode is set
(5), the red LED is alight (as‑delivered
status)
The fingerprint you read in first in
the group administrator mode is the
group administrator fingerprint.
• Draw the group administrator fin‑
gerprint over the sensor. The green
LED flashes for appr. 3 seconds, after
which the red LED lights up.
• Draw the group adminstrator
fingerprint over the sensor again.
The green LED flashes for appr. 3
seconds, after which the red LED
lights up.
• Draw the group administrator
fingerprint over the sensor for a
third time.
The green LED flashes for appr.
3 seconds, then stays alight. The
group administrator fingerprint has
now been scanned in and is valid.
It is now possible to scan in group
master fingerprints.
If a finger has been drawn over
the sensor and not recognized, the
red LED flashes for 3 seconds, after
which the red LED lights up continu
‑
ously.
Repeat the scanning‑in process.
Scan in a group master finger
-
• Draw the group administrator
fingerprint once over the sensor.
The green LED flashes for appr. 3
seconds then the red LED lights
up (scanning mode for the group
master fingerprint).
• Draw the group master fingerprint
over the sensor. The green LED
flashes for appr. 3 seconds, then the
red LED lights up.
• Draw the group master fingerprint
over the sensor again. The green
LED flashes for appr. 3 seconds, after
Содержание CFPM 611-02