3
40
36
72
M
12
20
14,5
52
Ø28
Ø28
EDI C7
36,3
108,6
14,6
40
36,3
Ø
29
28,7
M
12
EDI D1B
36
108,6
36
40
14,6
36,16
Ø
29
28,6
M
12
EDI E1B
2 .6 Scope of Supply
• Emergency stop button in slimline housing and M12 plug connection
• Holding bracket
• EDI C7, D1B: Reset button, button cap & identification plate
• EDI E1B: Operating button, button cap red & green
2 .7 Functions
• Confirm: Press the emergency stop button
• Unlock: Turn the emergency stop button
• Reset: Press the reset button (depending on the application)
• Two operating elements (depending on the application)
3 . Installation
3 .1 General installations notes
Make sure that emergency stop/emergency off button is mounted
at an easily accessible location .
The installation may only be carried out by authorized skilled personnel.
3 .2 Installation of the build-in version EDI Slimline housing
The emergency stop button is intended for vertical or horizontal installation. Install the
emergency stop button as shown in the illustration.
• Tighten the holding bracket.
• Attach the housing to the side of the retaining spring, pull against the spring pressure
and press on the housing. The housing engages.
• Connect the M12 connection cable to the connector plug.
Wall installation
Profile installation