7. Connector 

 

Amphenol connector – cable wiring   

 

pin 

color of wire   

function 

Power: 

red 

 

 

24VDC/0,5A , protected by fuse T 0,8A

 

blue

   

 

GND

 

 
Analog outputs: 

yellow  

 

Analog1 signal 4-20mA (intensity or position–depends on setting)

 

green   

 

Analog2 signal 4-20mA (intensity or position–depends on setting)

 

 

Digital outputs (push-pull): 

gray   

 

presence of material (detect = 24VDC/max. 50mA)

 

ping   

 

neg. presence of material (detect = 0VDC/max. 50mA)

 

black   

 

neg. alarm (all OK = 24VDC/max. 50mA, alarm = 0VDC)

 

 

Relay outputs: 

brown (thick w.) 

presence of material - NO (250V/5A)

 

white  (thick w.) 

presence of material - COM (250V/5A)

 

 
Relay inputs: 

brown  

 

external test (TEST - connect GND)

 

white   

 

remote change of value sets (connect to GND = switch to Set2).

 

 
Communication: 

purple  

 

isolated GND for RS485

 

red/blue 

 

DATA+ RS485

 

grey/ping 

 

DATA- RS485

 

 

 

  Amphenol PT 06 W 12-14 S 

 

Содержание SDIS - 1050

Страница 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Страница 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Страница 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Страница 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Страница 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Страница 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Страница 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Страница 8: ......

Страница 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Страница 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Страница 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Страница 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Страница 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Страница 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Отзывы: