The buttons have their numerical meanings: [↑] = 1 [←] = 2 [→] = 3 [

] = 4, then confirm PIN 

by [

]. 

There are two levels of user privileges to change the settings: 
 

Basic 

 

- for change the most important parameters- PIN: 

3412 

Advanced 

- for adaptation of the sensor on actual measuring site - PIN: 

2314 

 

 

- includes all items of the main menu

 

(PIN: 3412)

 

 
Use buttons 

[←]

 and 

[→] 

for move in menu items, press enter button

 [

to get access to 

submenu. Use escape

 [ ↑ ]

 button to get up in menu tree

Device remembers browsing history, 

you can use buttons 

[

or 

[ ↑ ] 

to fast move (e.g. if you change the switching threshold, you 

can check the device behaves in main menu and you can get simply back by pressing button 
[

]) few times. Specific value can be changed by pressing [

] (name will be flashing). Now use 

[←] and [→] to change value and confirm it by [

] (name stops flashing), or go back without 

saving by pressing [↑]. 
 

Sensor  

-> 

ValSet1 

-> 

Thre 25% 

value set 1, threshold is 25%

 

 

 

 

ValSet2 

-> 

Thre 50%

 

value set 2, threshold is 50% 

Set=Rel 

 

Rel – value set is chosen by external relay

 

Man1 - measure according ValSet1 
Man2 - measure according ValSet2 

 

Window 

 

-> 

Beg   5% 

beginning of measuring window (analog output =  4mA, 

                                                           position 0%)

 

End  95% 

ending of measuring window (analog output = 20mA, 
position 100%) 

 

 

 

 

 

 

SysInfo 

-> 

SDIS1050 

model number

 

 

 

 

SN:12001 

serial number

 

 

 

 

Tem=35°C 

temperature inside unit (reports alarm after exceeding 
60°C) 

 

Logout 

-> 

Logout ? 

confirm to logout (automatically after 10 min)

 

 

Display - advanced menu (PIN: 2314) 

 
Use buttons 

[←]

 and 

[→] 

for move in menu items, press button

 [

to get access to submenu. 

Use escape

 [ ↑ ]

 button to get up in menu tree

Device remember browsing history, you can use 

buttons 

[

or 

[ ↑ ] 

to fast move (e.g. if you change the switching threshold. We check the 

device behaves in main menu and you can get simply back by pressing button [

]). Specific 

value can be changed by pressing [

] (name will be flashing). Now use [←] and [→] to change 

value and confirm [

] it (name stops flashing), or to go back without saving button [↑]. 

 

 
Mode  LS 

-> 

LS  

- Loop Scanner mode   

operation mode 

 

- for measurement of hot material position 

 

 

 

HMD   - Hot Metal Detector 

 

- only for hot material presence detection (without position) 

 

Содержание SDIS - 1050

Страница 1: ...USER MANUAL Universal position sensor and hot metal detector SDIS 1050...

Страница 2: ...so that the infrared radiation is reflected to the photocell from each facet of rotating mirror very accurate even in the case when the entire sensing field is covered with hot material Radiation rec...

Страница 3: ...ing made of aluminum alloy suport wall with mounting stand adjustable in both directions adapted to the cooling unit with water and blowing air windscreen to prevent pollution connection of water and...

Страница 4: ...ndicular to the measured product When selecting the location of the sensor attention to the following must be paid Other source of infrared radiation in addition to the measured material can not inter...

Страница 5: ...onnecting the cooling water and air and setting changes the sensor mounting 4 4 1 Cooling The cooling channel housing is positioned allowing the cooling water sensor Conditions for cooling The sensor...

Страница 6: ...ron etc The temperature range depends on the infrared radiation of the product Angles standard sensor is supplied with a viewing angle of 50 degrees with a special mask inside the aperture angle can b...

Страница 7: ...Operating temperature 10 C to 60 C At an ambient temperature above 40 C it is recommended to cool sensor with industrial water at a temperature up to 25 C pressure of 1 2 bar flow rate of 1 2 l min P...

Страница 8: ......

Страница 9: ...selected gain Thre 25 selected threshold Mode LS selected operation mode of the sensor LS or HMD Laser 0 press button to light up the targeting laser for 2 minutes Laser 1 Failure message can be flas...

Страница 10: ...Set Rel Rel value set is chosen by external relay Man1 measure according ValSet1 Man2 measure according ValSet2 Window Beg 5 beginning of measuring window analog output 4mA position 0 End 95 ending o...

Страница 11: ...s setting End 0 90 distance between laser to end of meas window meters Outputs AnOut1 I output signal Analog 1 I intensity P position setting of analog AnOut2 P output signal Analog 2 I intensity P po...

Страница 12: ...detection is proportional to material position in the sensor s field of view Additionally sensor can be set to HMD mode hot metal detector sensor only detects if signal from PbS photocell exceeds thr...

Страница 13: ...ilters of output signals to improve accuracy or to avoid false detection By adjusting SiUp and SiDo values you can specify how many times signal must be detected befor output detection signal is set o...

Страница 14: ...sh pull C gray presence of material detect 24VDC max 50mA H ping neg presence of material detect 0VDC max 50mA M black neg alarm all OK 24VDC max 50mA alarm 0VDC Relay outputs E brown thick w presence...

Отзывы: