Software description
Settings window (Main tab)
In most cases, the Hann window will give the best results, by the aspect of main
lobe width and sidelobes level.
Note: The chosen weighting window for the fast Fourier transform has no impact on the
characteristics of the digital filters, the S-Meter values or other signal processing algorithms. The
selected weighting window only influences the spectrum and waterfall resolution.
S-meter
— selection of the detector used for S-meter. Peak – quasi-peak detector,
RMS – root mean square detector.
Rewind Length
— signal buffer size used in Time Machine function. ZeusRadio
software must be closed to the changes to take effect.
FBO Usage — on/off switch for FBO usage. FBO is used by default and the best
graphic performance is achieved. But in this case the waterfall can be missing on
weak PCs and FBO usage should be turned off. ZeusRadio software must be
closed for changes to take effect.
Hide When Minimized – show in the task bar or hide the program window to tray: If
set to "No", the window will remain in the task bar after minimization.
Pseudo 3D section
Here the parameters of the Pseudo 3D display are set.
Inverse Colors
— on/off switch for the color scheme inversion.
Color Scheme
— selection of color scheme.
Gradient Color
— color selection for the „Gradient“ color scheme.
SSB-Electronic GmbH © Page 34 of 88 V2.8.1 C
ontent is protected by Copyright.