Function Description:
1)
DC power supply port :
voltage range DC24 ± 10 %, power rating
greater than 50W.
2)
Gear selection port
There are eight editable stalls in the PT series controller, and eight sets of
different positive and negative pressure settings can be edited by
manual adjustment or PC software. Usage method : The IN-COM port
of the controller is connected to the output COM of the robot or PLC.
When the logical signals of SW1, SW2 and SW3 ports are 0, the first gear
is triggered. The pressure value of the clamping and opening of the end
fixture driven by the controller will be changed to the set value of the
first gear.
When the logical signal of SW1 port is 1, and the logical
signals of SW2 and SW3 ports are 0, the gear 2 is triggered, and the
pressure value of grasping and opening the end fixture driven by the
controller will be changed to the set value of gear 2. File three to eight.
The trigger voltage range is DC24V ± 10 % and the current is more than
100mA. According to the working condition, the appropriate gear
position corresponding to the positive and negative pressure output
value can be selected. Compared with the table below, the I / O signal
triggering the gear position can be input, and the positive and negative
pressure trigger port can be combined to drive the end fixture to
complete the grab or open.