![SRT SCB-PT Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/srt/scb-pt/scb-pt_user-manual_1354307010.webp)
SCB-PT
7
2. Function Description
2.1 Display function
Display features include pressure display and indicator light
1、Pressure display:
Display the real time output pressure value of the current air outlet;
display the set pressure during grabbing and opening debugging; alarm
information.
2、Indicator light:
Indicator lights are : completion / alarm instructions, grab adjustment
instructions and open adjustment instructions.
Complete / alarm instructions, when the end fixture completes the grab
or open action, the indicator lights green. When the controller detects
that the air inlet interface pressure does not reach the input pressure
range, or the end fixture cannot complete the operation normally, the
indicator light is red.
Grab adjustment indicator light : When the controller enters the manual
modification of the grab pressure setting value, the indicator light is
often bright, and it withdraws from the manual modification of the grab
pressure setting value, and the indicator light is extinguished.
Opening adjustment indicator light : When the controller enters the
manual modification of the opening pressure setting value, the indicator
light is often bright, and exits the manual modification of the opening
pressure setting value, the indicator light is extinguished.