3.4.7
Power Connection
Power is connected to the transceiver via the supplied 2 way power cable as
shown in Figure 15.
Figure 15 Power Connection
Table 4 Power Supply Connections
*Connection to an emergency power source is an IMO requirement for SOLAS
vessels.
The power supply current ratings and recommended fusing or circuit breaker
currents are as follows:
●
A 12VDC supply should be able to provide a peak current of 6.0A
and be fused at 10.0A.
Wire colour
Function
Connect to
Red
Power
12V or 24V DC power supply from
ships emergency power source*
Black
Power supply -
Power supply ground
Power connection