Operation
Page 47
Possible alarm conditions are listed Table 6.
Alarm
Description
TX Malfunction
This alarm will occur if the MMSI has not
been configured.
This alarm can also occur if the radio
hardware has failed to select the correct
frequency, that the output power is too low or
a transmitter shutdown has occurred.
In this situation, ALR 001 is output.
The alarm will be cleared if the transmitter
recovers normal operation.
RX Channel
x
malfunction
This alarm occurs should the receiver
hardware malfunction. The receiver is
identified by the value of x (as shown below).
The following alarms will be generated in this
condition:
ALR 003 - Rx Channel 1
ALR 004 - Rx Channel 2
ALR 005 - DSC (Channel 70)
If the receiver returns to normal operation this
alarm will be cleared.
Antenna VSWR exceeds
limit
This alarm occurs if there is a problem with
your antenna or antenna connection.
No valid COG information
This alarm occurs if the AIS transceiver has
no valid Course Over Ground information
from any connected sensor.
No valid SOG information
This alarm occurs if the AIS transceiver has
no valid Speed Over Ground information from
any connected sensor.
Содержание 427-0002B
Страница 1: ...AIS Class B transceiver Installation and operation manual ...
Страница 16: ...Notices Page 14 ...
Страница 18: ...Introduction Page 16 ...
Страница 24: ...Installation and configuration Page 22 Figure 5 Desk mounting the AIS transceiver ...
Страница 66: ...Technical information Page 64 ...
Страница 74: ...Technical specification Page 72 ...
Страница 75: ......
Страница 76: ...201 0707 1 Manufacturer s code 427 NMEA 2000 Product code xxxxx ...