![SRS Labs GMC12-WL-12H6 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/srs-labs/gmc12-wl-12h6/gmc12-wl-12h6_instruction-manual_1354204007.webp)
(7 /16)
GMC12-WLV series Base unit
GMCseries front panel
Hoist protection:
GMC12:
Each three hoists are protected by single C16/3p MCB
Power key switch positions:
OFF:
Power OFF /Only battery charger is active in this state/
PICKLE:
Power to the hoist is enabled
AUTO:
Power to the hoist is enabled when GO command is received
GROUP STOP key switch positions:
OFF:
Trip of any breaker or mains GFI breaker will not cause E-STOP
ON:
Trip of any breaker or mains GFI will cause E-STOP of the unit
MODE key switch positions:
Local / LINK:
Device works via local control or via network in linked operation
Radio Remote: Device is controlled via wireless radio remote
RESET:
RESET button works for the SIL3 E-STOP relay reset. RESET needs be pressed every time after the
unit is turned ON, the E-STOP mushroom has been pressed or when the GROUP STOP has been
activated.