Functions and Control 

 
Motor  Controller  has  been  designed  to  control  from  1  to  12  electrically  compatible  motors,  either 
separately  or  simultaneously  –  controlled  via  switches  located  on  front  panel  or  wireless 
remote/pendant. Optionally you can link GO/STOP button by link connector. 
 
Each  device  is  equipped  with  unique  APA  /Automatic  Phase  Align/  module  that  guarantees  that  on 
any  alignment  of  input  phases  the  motors  will  move  in  the  correct  direction.  If  any  line  wire  is 
disconnected,  the  hoist  controller  stops  to  ensure  safe  operation.  Unit  is  also  equipped  with  AVM 
/Automatic Voltage Metering/ module. This module checks the main voltage for  AC400V  +-20% and 
the star configuration. if there is any problem with the main voltage, you’re notified, and unit will not 
run any hoist. 
 
Unit will not work when: 

 

One phase is missing 

 

Under-voltage is present on lines 

 

Over-voltage is present on lines 

 
All electrical components carry their own individual cSA/UL, CE and comply with European Directives. 
The  components  are  housed  in  robust  steel  19"  rack  casing  with  powder  coating.  Complete  unit 
complies with the CE according the Certification of conformity attached to this manual. 
 

Operation 

 
The  motors/hoists  connected  with  the  GMCseries  controller  can  be  activated  individually  or 
simultaneously  using  the  GO  switch  located  on  the  front  panel  or  wireless  remote.  Units  can  be 
optionally linked together to create bigger systems. 
 

How to start 

 

 

Connect  the  CEE32/5p  plug  to  the  AC400V  +-20%  power  supply  –  turn  the  key  to  ON 
position.  When  the  main  power  is  OK,  the  power  LED  will  light  green,  otherwise  the  unit  is 
OFF. Check phase voltages, frequency and contact the manufacturer if help is needed. 

 

 

Connect the plugs for the electric hoists to the output sockets. 

 

 

Check that the emergency STOP mushroom on the device is not engaged or any other linked 
device in system. 

 

Move lever on the front panel or WMC remote corresponding to each motor to the required 
position: 

o

 

UP - Lever in upper position 

o

 

STAY – Lever in middle position 

o

 

DOWN - Lever in lower position  

 

 

Pushing the GO button will activate the motors to move simultaneously 

 

Releasing the GO button will stop the movement of the motors simultaneously. 

 

When the device is not being used, it is highly recommended to turn it OFF by the key 
located on the front panel. 

 
 

Содержание GMC12-WL-12H6

Страница 1: ...out the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the power to the equipment is disconnected before opening the equipment or comm...

Страница 2: ...dards of design manufacture and the intended use of this equipment Do not operate in an explosive atmosphere Do not operate this equipment in the presence of flammable gases or fumes Operation of any...

Страница 3: ...with powder coating Complete unit complies with the CE according the Certification of conformity attached to this manual Operation The motors hoists connected with the GMCseries controller can be act...

Страница 4: ...in motor to the desired direction The associated LED should light green for UP or red for DOWN direction Hold the GO button until the motor is moved the desired height then release WMCseries remote co...

Страница 5: ...cal mode on the Base unit is ON only when one or more direction switches are in active position UP or DOWN DIRECTION SWITCHES They allow changing of the direction of movement for each motor hoist sepa...

Страница 6: ...cable remotes can be destroyed When WMC remotes are linked the GO and STOP buttons are linked so press of any STOP and GO button will work for both linked devices Link of Base WLV units Up to 30 Base...

Страница 7: ...P STOP key switch positions OFF Trip of any breaker or mains GFI breaker will not cause E STOP ON Trip of any breaker or mains GFI will cause E STOP of the unit MODE key switch positions Local LINK De...

Страница 8: ...ists is turned OFF DIRECTION SWITCHES They allow changing the direction of movement for each motor hoist separately or in groups LED close to the switch indicates the movement direction Charger status...

Страница 9: ...9 16 GMCseries rear panel...

Страница 10: ...ered devices Protected by C16 1p breaker on the front panel Output connectors wiring Harting 24 Female Pin Function 1 L1 2 L1 3 L2 4 L2 5 L3 6 L3 7 M2 down 8 M2 common 9 M2 UP 10 M4 down 11 M4 common...

Страница 11: ...ommon 2 Data Data Minus 3 Data Data Plus 4 DC1 Power supply for CMC DC12 36V 5 DC2 Power supply for CMC DC12 36V Loadcell E STOP connector Neutrik NC4 FAH Pin Function note 1 DC24 36V Connected to 3 2...

Страница 12: ...oist controller comes with a 2 year manufacturer s warranty For extended warranty conditions please contact the manufacturer at sales srs group com The warranty covers the original factory installed c...

Страница 13: ...p com 421244681417 Declares that the product Name of product GMCseries hoist controller GMC12 WLV GMC8 WLV variants Types MC12 WLV 3H24 Low voltage hoist motor controller Corresponds with following ha...

Страница 14: ...14 16...

Страница 15: ...15 16...

Страница 16: ...ubject to change without notice Document GMC12 WLV 3H24_en_manual_M237 Version1 0 Actual as of 6 November 2018 SRS Group s r o Rybnicna 36 D 831 07 Bratislava Slovakia Phone 421 2 44 681 417 Fax 421 2...

Отзывы: