background image

Model SR565

i

 Bariatric Stand-On Scale 

Operating and Service Manual - S/N 1000+ 
Part No.  MAN565

i

_130314 

 

Page 1 of 20 

 
 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977     Fax: 716-693-5854    URL: 

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2013

 

S

Instruments, Inc. 

 
 

by 

S

 Instruments, Inc. 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 

Operating and Service  

Manual 

Serial Numbers: 1000 + 

M

o

d

el

 S

R

5

6

5

Bariatric Stand-On Scale 

 

Содержание SR565i

Страница 1: ...314 Page 1 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SInstruments Inc S by S Instrume...

Страница 2: ...TEM DESCRIPTION AND INTENDED USE 6 MAINTENANCE AND CLEANING 7 STORAGE AND TRANSPORTATION 7 SPECIFICATIONS 8 BUTTON FUNCTIONS 9 BASIC SYSTEM OPERATION 10 BATTERY REPLACEMENT 12 THEORY OF OPERATION 13 C...

Страница 3: ...ents Inc PACKING CHECKLIST DESCRIPTION QUANTITY Box 1 BASE ASSEMBLY 1 ea MAST ASSEMBLY with DISPLAY and HEIGHT BAR 1 ea DISPLAY UNIT WITH CABLE 1 ea PACKAGE OF SIX 6 D CELL BATTERIES 1 ea 3 8 16 FLAT...

Страница 4: ...correctly in the Base Assembly STEP 3 Figure 1 Insert the four 4 3 8 16 screws 4 into the holes in Mast Assembly and Base Assembly as indicated Secure the Mast Assembly by tightening the screws into...

Страница 5: ...on INSTALLING OPTIONAL PRINTER STEP 1 Mount the Printer Mast Bracket 8 to the rear of the Mast Assembly 1 using the two 2 mounting screws provided NOTE The three holes on the Printer Mast Bracket shou...

Страница 6: ...weight readings before needing replacement This eliminates the need for an external battery charger or the danger of an AC power supply cord on a portable scale The patient s weight is displayed on a...

Страница 7: ...or general cleaning and disinfecting STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the batteries To maintain proper operation of this instr...

Страница 8: ...ayed resolution for calibrated range AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds RECALL Recalls last stored weight height and BMI AVERAGING Automa...

Страница 9: ...r flashes then remains solid when stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Als...

Страница 10: ...ring scale output Use the UP or DOWN arrow buttons to select between PRINT and EHR Press ENTER to save changes Setting printout orientation Use the UP or DOWN arrow buttons to select between PRINT INV...

Страница 11: ...ng the system This will ensure that the patient s NET weight will be displayed It is recommended that the system be zeroed prior to each new patient CALCULATING BMI Press to calculate BMI When the BMI...

Страница 12: ...the scale on its side and unscrew the four 4 screws in the Battery Compartment Cover located on the base of the unit between the wheels STEP 3 Remove and replace ALL six 6 D cell batteries Refer to Ba...

Страница 13: ...meters serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer produces a small current which nulls the output of the amplifier for an unloa...

Страница 14: ...the maximum scale capacity The second weight should be less than half of the first weight DO NOT USE barbells or un calibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH button...

Страница 15: ...se the UP arrow button to select the digit and the DOWN arrow button to change digit Press ENTER to save changes STEP 4 Press the MENU button until HALF 500 00 Lb is displayed Set the HALF value of th...

Страница 16: ...cords EMR Electronic Health Records EHR technology is supported by the i series scales from SR Instruments The EMR EHR software is not included with scale There are many different EMR EHR software ava...

Страница 17: ...ttery Wait five seconds then re install the battery and try the WEIGH button again The display lights appear to work but do not respond to button activation Check to ensure the membrane switch label i...

Страница 18: ...truments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Inst...

Страница 19: ...ting and Service Manual S N 1000 Part No MAN565i_130314 Page 19 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstrument...

Страница 20: ...000 Part No MAN565i_130314 Page 20 of 20 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2013 SInstrum...

Отзывы: