Страница 2: ...resi stor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch ACVoltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average c...
Страница 3: ...LWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by ...
Страница 4: ...utput PowerCon compatibleACpowerIn Outconnectors Neverdisconnectthepowercordbypullingortuggingonthecord DMX Quick Reference 1 3 4 7 8 16 Channel Modes Channel Mode Function 1 3 4 7 8 16 1 1 1 1 1 Master Dimmer 0 100 2 2 2 Red segment Intensity 0 100 3 3 3 Green segment Intensity 0 100 4 4 4 Blue segment Intensity 0 100 5 5 5 White segment Intensity 0 100 2 2 6 6 6 Flash duration 0 full on 1 3 3 7 ...
Страница 5: ...0 100 Red1 Intensity 0 100 2 Green Segment Intensity 0 100 Green1 Intensity 0 100 3 Blue Segment Intensity 0 100 Blue1 Intensity 0 100 4 White Segment Intensity 0 100 White1 Intensity 0 100 5 Red2 Intensity 0 100 6 Green2 Intensity 0 100 7 Blue2 Intensity 0 100 8 White2 Intensity 0 100 Figure 1 The Storm1000 RGBW Pin Up Picture ...
Страница 6: ...put switch mode power supply with an inter nal fuse Under normal operating conditions the fuse should not require replacement The fuse is field replaceable however it is an advanced procedure suited to qualified individuals Should your Storm1000 RGBW fuse require replacement please contact your dealer for instructions ...
Страница 7: ...as reliably over long distances In any event the cable should have the following characteristics 2 conductortwistedpairplusashield Maximumcapacitancebetweenconductors 30pF ft Maximumcapacitancebetweenconductor shield 55pF ft Maximumresistanceof20ohms 1000ft Nominalimpedance100 140ohms Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end Duh ...
Страница 8: ...tails a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection TakeItToTheNextLevel SettingUpDMXControl Step1 Connectthemaleconnectorofthe DMXcabletothefemaleconnector output onthecontroller Step2 Connectthefemaleconnectorofthe DMXcabletothef...
Страница 9: ...e operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIP switches Secondarily the fixtures that follow may also require a slave setting Check the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture can be mounted in any orientatio...
Страница 10: ...ng order UP Scrolls through menu options in ascending order ENTER Used to store the current menu or option within a menu The LCD control panel display shows the menu items you select from the menu map on page 10 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER To navigate through the LCD c...
Страница 11: ...ure Time ENTER Total RunTime Config DMX Status Value Hold Holds the last DMX values if signal is lost Value Clear Clears the DMX values if signal is lost Display Mode Display Mode LCD Display ON or Auto OFF Temp Unit CS Channel 1 1ch DMX mode Channel 3 3ch DMX mode Channel 4 4ch DMX mode Channel 7 7ch DMX mode Channel 8 8ch DMX mode Channel 16 16ch DMX mode Pixel 4 4ch DMX pixel control Pixel 8 8c...
Страница 12: ... ESC button until you reach the Address screen Master Slave Mode 1 Disconnect fixture s from any DMX signal source 2 Set each fixture to matching DMX modes 3 Connect all fixtures together via DMX The first fixture in the DMX chain will be the master followed by the slave fixtures 4 Connect DMX controller to the master unit for DMX control Load Default Settings 1 Press the UP DOWN buttons until you...
Страница 13: ... DMX Status then press the ENTER button 4 Use the UP DOWN buttons to select either Value Hold orValue Clear 5 Press the ENTER button to confirm LCD Display On Auto Off Display mode On will keep the LCD illuminated continually Auto will shut the dis play off after 30 seconds of inactivity 1 Press the UP DOWN buttons until you reach Config 2 Push the ENTER button and navigate to Display Mode 3 Push ...
Страница 14: ...t 2 Intensity 0 100 11 000 255 Blue1 Segment 3 Intensity 0 100 12 000 255 White1 Segment 4 Intensity 0 100 13 000 255 Red2 Segment 5 Intensity 0 100 14 000 255 Green2 Segment 6 Intensity 0 100 15 000 255 Blue2 Segment 7 Intensity 0 100 16 000 255 White2 Segment 8 Intensity 0 100 DMXValues In Depth 8 Channel Mode Menu Sub menu Function 1 000 255 Master Dimmer 0 100 2 000 255 Red segment Intensity 0...
Страница 15: ... Menu Sub menu Function 1 000 255 Dimmer 0 100 2 000 255 Flash Duration 0 100 3 000 255 Strobe Rate 0 30Hz 4 000 005 006 042 043 085 086 128 129 171 172 214 215 255 Built In Programs No function Ramp up effect slow fast Ramp down effect slow fast Ramp up down effect slow fast Random effect slow fast Lightning effect slow fast Spike effect DMXValues In Depth 3 Channel Mode Menu Sub menu Function 1 ...
Страница 16: ...2 Intensity 0 100 Troubleshooting Symptom Solution Fixture Auto Shut Off If it is stopped or dimmer than normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating No Light Output Check to ensure fixture is operating under No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if appli cable Chase Speed To...
Страница 17: ...re type and size Check the power cord as well make sure there is no damage that could cause electrical shock never remove the ground prong There are no user servicable parts in this fixture Do not attempt to open and repair this fixture Return to the factory for repair Tech Specs Power OperatingVoltage 220 240VAC 50 60Hz Power Consumption 800W Max 5A pf 75 Light Source LED 630RGB LEDs 630 white le...