background image

 

 

 
 

 

 

2.

 

Safety Instruction 

 

 

Safety Notes 

 

! Enquire the skilled people before any repair;   

! Always make sure disconnect from the power source before setting up, serving and moving;. 

Avoid direct eye exposure to the fixture when it is on;   

                                               

 

    Safety 

instruction 

 

● 

Make sure the power supply voltage are consistent with this lights

Ensure the use of voltage is in the range 

of the request technical parameter. 

Before the installation, please check the light’s fasteners and mechanical structure have been received in 

good condition and appear no damage.   

This light is designed for indoor use; working temperature is lower than 40 degree.   

The fixtures maybe mounted in any position provided there is adequate room for ventilation. Make sure 

there are no inflammable and explosive items (ornaments) in 0.5 meters away.   

Yellow / green cabling earthling safety; no flicker when the fixture is working on.   

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Edgy

Страница 1: ...User Manual Squareled Edgy Akku Wireless 4x25W RGBAW ...

Страница 2: ...SquareLED Edgy Akku Wireless 4x25W RGBAW 5in1 USER MANUAL ...

Страница 3: ...5 DMX Control Function 5 6 Display Operation instruction 8 7 Instruction for compatible Sweden DMX wireless module 14 8 Ifrared keyboard operation 15 9 Operating Control Instruction 16 10 XLR cable connecting 16 11 Trouble Shooting 17 Please read over this manual before operating the light ...

Страница 4: ... shows It adopts high power 5 in 1 LED which refers to single LED is made of R G B A W 5 IN 1 LED And long life span low consumption good color mixing effect and high brightness are the most prominent features Each kind of LED can be independently dimmed The built in program includes dimming strobe eotic gradual change fading and so on It uses power switch performs low weight and consumption stabl...

Страница 5: ...age is in the range of the request technical parameter Before the installation please check the light s fasteners and mechanical structure have been received in good condition and appear no damage This light is designed for indoor use working temperature is lower than 40 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflamm...

Страница 6: ...3 3 Outside Size Picture ...

Страница 7: ...gnal DMX512 Control mode stand alone Master Slaver Ifrared keyboard control 2 4G wireless DMX512 Channel 16CH 11CH 10CH 11CH 6CH 5CH Function Effect dimmer strobe gradual change Battery charge time 5 5 hours Full power battery duration 5 5 hours Cooling mode Natural Convection Anti electricity intension 1 5KV Insulation Resistance 2MΩ Beam Angle 15 25 45 60 Optional Net weight 9 52Kg ...

Страница 8: ...255 B2 CH9 CH10 CH10 0 255 A2 CH10 CH11 CH11 0 255 W2 CH7 CH12 0 5 No strobe 6 20 Not synchronous strobe slow to fast 21 60 Synchronous strobe slow to fast 61 100 Electronic Sinewave slow to fast 101 140 Random Strobe slow to fast 141 180 Opening pulse slow to fast 181 220 Closing pulse slow to fast 221 255 Electronic Squarewave slow to fast CH8 C H8 Prior to CH10 CH13 CH13 Prior to CH15 0 5 No ef...

Страница 9: ...61 165 AUTO 22 166 170 AUTO 23 171 175 AUTO 24 176 180 AUTO 25 181 185 AUTO 26 186 190 AUTO 27 191 195 AUTO 28 196 200 AUTO 29 201 205 AUTO 30 206 210 AUTO 31 211 215 AUTO 32 216 220 AUTO 33 221 225 CHASE1 226 230 CHASE2 231 235 CHASE3 236 255 Reserved CH9 CH14 0 255 Auto speed fast slow AT01 AT05 0 255S AT06 AT33 0 25 5S CH10 CH15 R GB color mixing instead Virtual colour wheel 0 10 No effect 11 B...

Страница 10: ... Blue 0 White 0 step 172 210 Red full Green 0 Blue up White 0 proportional 211 Magenta Red full Green 0 Blue full White 0 step 212 250 Red down Green 0 Blue full White 0 proportional 251 255 Blue Red 0 Green 0 Blue full White 0 step CH11 CH16 0 10 Use the dimmer mode which menu had set up 11 20 Linear curve 21 30 Square law curve 31 40 Inverse square law curve 41 50 S curve 51 60 Linear curve and ...

Страница 11: ...parameter increments DOWN menu selection or parameters decrease Menu Tree TAB LEVEL 1 LEVEL 2 LEVLE 3 LEVEL 4 ADDR Address 001 512 STAT Static control R1 0 255 G1 0 255 B1 0 255 A1 0 255 W1 0 255 R2 0 255 G2 0 255 B2 0 255 A2 0 255 W2 0 255 SHUT 0 255 SET Set SIGN DMX signal selection 2 4G wirelsee CABL Cable WIRE Wireless set REST reset YES NO KEY ...

Страница 12: ...SQR square law smooth ISQR inverse square law smooth SCUR S curve smooth DISY Display set ON Permanent on 2 OFF 2 minutes off SHOW ADDR BAT LOCK YES NO CTST Custom color set CT01 R 0 255 G 0 255 B 0 255 A 0 255 W 0 255 CT10 AUTO Auto AT01 RUN RUN RUN RUN AT33 RUN ATSP Auto speed 0 255 S CHS1 Chase 1 RUN CHS2 Chase 2 RUN CHS3 Chase 3 RUN PROG Program CHS1 Chase 1 SC01 Scene 1 R1 0 255 G1 0 255 B1 0...

Страница 13: ...d will synchronously running without manually set as slave When power cycle it will jump to the position and running again And in these position it will not return back to the default display after two minutes 6 1 DMX ADDRESS SETTING 1 Press the ENTER button in ADDR menu then enter to the DMX address setting 2 Press the UP DOWN button to select 1 512 numerical value 3 Press the ENTER button to esc...

Страница 14: ... CAL menu then enter to the color cast calibration setting 2 Press the UP DOWN button to select RED GREEN WHITE 3 Press the UP DOWN button to set up the 0 255 numerical value 4 On the USE interface pressing YES button means valid NO means invalid 5 Press the ENTER button to escape and save Illustrations When pressing the YES button which means valid on the USE interface the actual output value of ...

Страница 15: ...isplay setting 2 Press the UP DOWN button to select ADDR BAT 3 Press the ENTER button to escape and save 6 11 AUTO LOCK KEY SETTING 1 pressing the MENU UP DOWN ENTER MENU UP DOWM ENTER MENU UP DOWN ENTER That means the unlock method is to press the MENU UP DOWN ENTER three times cyclically and the time between press two keys can not over 3S or start anew 2 The methods are using need to meet certai...

Страница 16: ... TIME WAIT USE 7 Press the UP DOWN button to set up the parameter which are needed 8 Press the ENTER button t o escape and save Illustrations When USE is set to be NO or the parameter of TIME is 0 it will not run this scene When WAIT is set to be FADE time the running process isas the following chart showing 6 15 CHECK THE LIGHTING INFORMATION 1 Press the ENTER button in INFO menu then enter to th...

Страница 17: ... before sending the parameter 2 The information of ADDR CAL can t be sent can t be downloaded each other 3 There will be an automatic reset of the other projectors after receiving parameter correctly 7 Instruction for compatible Sweden DMX wireless module 1 There are 4 modes compatible Sweden receive mode green indicator compatible Sweden transmit mode blue indicator normal mode yellow indicator c...

Страница 18: ...and transmit data 6 User defined function is not available 7 Notice compatible Sweden DMX mode in this lights has complete data for sending and receiving but transmit function is not available here 8 Infrared keyboard operation ...

Страница 19: ...ixtures work in master mode it will send out the signal for the slave synchronous with it To avoid the host signal and DMX512 signals interfere with each other should cut off the DMX512 signals The signal lines are longer than 60 meters 20 lamps should increase a signal amplifier 10 XLR cable connecting XLR cable The standard connection way of the XLR is one end connects to the male plug and the o...

Страница 20: ...arted normally Check the power connection is correct or not Please detect the voltage Power supply is damaged or incorrect connected Call a qualified personnel to fix it Connection of control board is not correct Call a qualified personnel to fix it Out of console s control is connected correctly or not It means having signal if it shows twinkling of the decimal point which in the lower right corn...

Страница 21: ... will damage or interfere the DMX electric circuit The beam appears dim the brightness declines obviously Check whether the CAL is started or not and the set value is too small Check whether the POW is in over temperature protection situation or not if yes please take measures for ventilation ...

Страница 22: ...Das LichttechnikhausVertriebs GmbH Rudolf Diesel Str 3 D 89312 Günzburg Telefon 49 0 82 21 207 98 0 Fax 49 0 82 21 207 98 69 E Mail info lth gmbh de Web www lth gmbh de ...

Отзывы: