CV/EN (1009) 5.3
Installation
21
CombiPrime V
3.7
Vacuum pump with service liquid tank
3.7.1
Mounting of accessories
• Connect a pipe to the overflow of the service liquid tank to discharge excess service
liquid and extracted air.
• The pump is supplied with the exhaust pipe connected to the pump cover.
3.7.2
Connection diagram with service liquid tank
3.7.3
Indication of connections
The suction, delivery and service liquid connections of the vacuum pump are indicated
both on the drawings and on the vacuum pump by the letters
S, P
and
W
. Suction point
PC
is the connection to the space behind the impeller.
Indications used in figure 4 through figure 8:
Figure 4:
Connection diagram with service liquid tank.
V/O
Venting / Overflow
S
Inlet vacuum pump
SP
Exhaust pipe
P
Outlet vacuum pump
W
Service liquid
PC
Pump connection (=air-extraction connection centrifugal pump)
SF
Filter in suction pipe (only in figure 6)
1
Service liquid tank
2
Vacuum pump
5
Check valve
6
Air inlet valve